EFTA00802584.pdf
📄 Extracted Text (214 words)
' blown fuse, low voltage, fuse replaced and left for testing stack removed from module
cluster 1
stack module 1 module 2 module 3 module 4 module 5 module 6
1 51 52.3 52.3 52.1 52.2 52.2
2 52.3 52.3 50.2 52 52.2 50.9
3 3.8 52.3 52.3 51.7 52.2 52
4 52.3 52.3 52.3 52.3 19.9 51.7
5 47.3 51 3.9 52.1 42.2 51.3
6 52.3 52.3 48 52.1 52.2 52.1
7 52.3 48.3 52.3 51.5 52.2 52.2
8 52.2 52.3 52.3 52.2 47.5 52.2
9 49.4 52.3 52.5 51.3 51.1 34
10 52.2 52.3 52.3 51.8 52 52.1
11 2.3 52.3 47.6 50.9 0.7 0.763
12 30.9 52.3 52.3 2.9 16.26 49.5
cluster 2
stack module 7 module 8 module 9 module 10 module 11 module 12
1 0.18 49.1 1.2 49.1 1.5 47.7
2 0.18 49.4 1.1 1.5 49.2 49.2
3 49.6 41.6 47.8 48.5 39.5' 48.1
4 2.7 49.2 47.8 49.1 0.7 49.1
5 3.7 15 4.2 23.6 0.6 49.9
6 44.1 49.1 43.1 44.7 0.7 49.7
7 5.3 13.8 46 45.8 47.8 49.2
8 42.9 49.1 48.3 18.6 49.2 47.8
9 2.3 41.4 49.5 44 40.5 40
10 2.3 19.3 46.7 0.9 0 14'
11 42.6 8.3 45.6 0.4 1.1 48.7
12 45.4 48.7 49 0 49 15'
EFTA00802584