EFTA01773967.pdf

DataSet-10 5 pages 933 words document
👁 1 💬 0
📄 Extracted Text (933 words)
From: Pete Rawson Sent: Saturday, April 9, 2016 11:02 PM To: Jeffrey E.; lvjet Subject: Re: Hello Jeffrey, Larry knows that I am long winded with my responses, Here is my brief- Feel free to read all at your leisure- They are mostly my thoughts so far- I suspect that the right precooler (fan air) modulating valve is bad. They are both original. From the last video and Photo's; The readings show that the left side is being given a voltage to th= Torque motor sending a pressure to command the valve to be partially=dosed. Zero volts, zero pressure is for full open, ie: cold air into the precoo=er and lowering the temperature into the supply system. The signals show a steady state condition; 3 Volts, 3 PSI. The valve has been sent signals, and has responded correctly, and theref=re is in the proper position to maintain 400 degrees in the supply system./p> This is being monitored, and controlled by the controller, and the senso= inputs. EFTA_R1_00087131 EFTA01773967 There is no signal from the valve, the temperature monitoring circuit co=trols the changes required. The right side shows that it is being commanded to close due to the high=voltage, and pressures. ( 9 volts, 9 PSI) It seems that the signals are not being followed, or that the valve cann=t respond to them. Since the control system does not see the temperature change from the se=sors, it continues to increase the pressure to the valve. Brief complete- As for the full version- This was done as a draft, please excuse any duplication for items noted =n the brief, these were my original thoughts. I agree with all that you stated- The guidelines are for what the electrical system does. We have found a bad controller- the sweeping voltage and pressures, and =eplaced it- There was also a bad sensor that was replaced- We have swapped the pressure regulator/torque motors. Latest swap was the Anticipators. There seem to be multiple issues, and we are narrowing them down. I believe that the electrical and control systems are now operating norm=lly. Now on to the air side of it. From the last video, and photo's- 2 EFTA_R1_00087132 EFTA01773968 I believe that the left side is operating properly. The Temp is being controlled by sending a regulated pressure to the valv=, and it responding. The pressure supplied is closing the valve, and maintaining the 400 Degr=es requested. No voltage equals no pressure, Valve open, lowering the Temperature. The right side shows giving a close signal to the precooler (fan air) va=ve. High Voltage, and pressure supplied to the Valve on that side to close, =nd increase the temperature. That side doesn't seem to respond. The valve has a 4 inch input/output side. The control line is about 1/4 inch. That is one of the lines that we found collapsed, and started us on this=direction. Is it possible that the supply air is not being able to overcome the pre=sure at the valve? The pressure read at the panel is a control pressure, also known as &quo=;Muscle air". Maybe the input air at the 4 inch diameter inlet, can overcome the contr=l air. I again suspect an issue with the LP valve- There is no valve position, or feedback signal from the valve- The electrical signal is showing to close the valve, The pressure is also showing to close the valve. One way to check is to select Wing heat on- The system causes the applicable side to remove the signals, and allow t=e valves to go full open. Wing heat is not normally used at altitude- 3 EFTA_R1_00087133 EFTA01773969 When the aircraft is in below 0 degrees temps, there is no reason, since=any precip won't stick. Ask Larry if there any issues with selecting the wing heat on at altitud=- I don't believe that there are any limits to the altitude, but the fuel =urn will be increased. Just a quick check- The ground checks for the precooler system are limited, Engines running, there should be no air flowing from the lower pylon hea= exchanger at idle- Increase power, and there should be airflow noticed. My training manual shows that the valve should start to open at about 74= HP on the ground, Wing heat on, there should be airflow. Regards, Pete From: Jeffrey E. <[email protected]> Sent: Saturday, April 9, 201610:13 AM To: lvjet; Pete Rawson Subject: The precooler fan air modulating valve (installed in the e=gine pylon) controls fan air airflow to the precooler in order to maintain=a nominal 400° F (204° C) bleed air temperature. Precooler outlet air =emperature is continuously monitored by a precooler outlet temperature sensor and a precooler temperature contr=l anticipator sensor. Outputs from these sensors are transmitted to the pr=cooler temperature controller. The controller, in turn, will change the ou=put voltage to the servo air pressure regulator and torque motor. The servo air pressure regulator and torque mo=or then changes the electrical signal to a filtered pneumatic signal, posi=ioning the precooler fan air modulating valve accordingly please note 4 EFTA_R1_00087134 EFTA01773970 The information contained in this communication is confidential, may be attorney-client privileged, may constitute inside information, and is intended only for the use of the addressee. It is the property of JEE Unauthorized use, disclosure or copying of this communication or any part thereof is strictly prohibited and may be unlawful. If you have received this communication in error, please notify us immediately by return e-mail or by e-mail to [email protected] <mailto:[email protected]> , and destroy this communication and all copies thereof, including all attachments. copyright -all rights reserved 5 EFTA_R1_00087135 EFTA01773971
ℹ️ Document Details
SHA-256
2feb2e03bb01b024a194d0eb5f7cc71cbea0189bdc79a003dc91a0eccd903b68
Bates Number
EFTA01773967
Dataset
DataSet-10
Type
document
Pages
5

Community Rating

Sign in to rate this document

📋 What Is This?

Loading…
Sign in to add a description

💬 Comments 0

Sign in to join the discussion
Loading comments…
Link copied!