EFTA01735378
EFTA01735386 DataSet-10
EFTA01735392

EFTA01735386.pdf

DataSet-10 6 pages 1,025 words document
P17 P24 V16 D3 P18
Open PDF directly ↗ View extracted text
👁 1 💬 0
📄 Extracted Text (1,025 words)
SIEMENS Technical Specification Sheet Rev. 1, December 2010 Field Panel Web Server Security The Web Server is secured from IT security threats weenier.. by means of password-protected operator access. The Web Server uses password encryption. User accounts can be individually configured for customized access privileges. Operator sessions may be configured to automatically log off during periods of user inactivity. The Field Panel Web Server provides a Web-based The Field Panel Web Server is compatible with Graphical User Interface (GUI) compatible with standard IT security policies and tools established BACnet® networks. Using the Web Server, the within a particular facility, and can be protected facility operator can easily monitor and control the within that environment. APOGEE® Building Automation System through an intuitive Web-based user interface. Browser/Client Requirements Description • Session cookies enabled The Web Server allows system-wide access through • Adobe® Flash® Player Plug-in 10.1 or later a single log-in. Web pages are populated with data installed from any BACnet IP-enabled PXC controller and Features associated Field Level Network (FLN) devices. The Field Panel Web Server encompasses the The Web Server runs on standard PXC controllers, following operator applications: eliminating the need for separate high-cost 'web appliances' or dedicated web servers. This means • Graphical Monitoring and Control that the same APOGEE field panel can serve as an • Network Layout automation controller, with full building automation and I/O features, and provide the user with system • System Status Bar information and access via a web browser. • Alarm Status and Acknowledgement The use of web services for communication ensures that any web browser with Adobe® Flash® is able to • Point Commanding access the Field Panel Web Server. • Scheduling A Web Server-enabled controller can accommodate • Reporting an unlimited number of user accounts and • Graphical Trend Display simultaneous users. • User Interface Customization • Online Database Editing Document No. 149-1000 Page 1 of 6 EFTA_R1_00017740 EFTA01735386 Graphics System Status Bar INIECIWN =MI --11 • 0 • • • Visual indication of new alarms and unacknowledged alarms • Visual indication of out of service, faults, and failed devices FAIT a-4; Alarm Status and Acknowledgement . •I •Los Repo.. • Customized system graphics • Live animation of equipment • Real-time point values and status updates • Link to system schedule and% or historical trend • Ability to view, filter, and acknowledge system Network Layout alarms from a single page C, • v • e: et •!,•••.t, Ahul Point Commanding • IT. S•• A111111 OGRAM:TOTKW • IL Sie bl.t..1 AMU ChoNV • Change point values • L See BLDG1 AHUI worn/ • Place points "Out of Service" BLDG! AHUI PAH • Command BACnet MS/TP and P1 FLN points DLOG1 AHUI PAT • rd ., Graphics Scheduling • 71 MST•TUE.02 ▪ .•••••• >0.10 1611 • ES12.I3TECOI • I_ Ssernens13 00131 U • Local **Trends • • • Schedules • ▪ Gre•Pmcs ••• 0111.0. • f.PITUNI 513.A1EC03 ..S13.ATECO4 • 513.TEC01 . 1 S13.TEC02 • View network layout • View schedules in a daily, weekly, or monthly • View BACNET MSITP and P1 FLNs view • Navigate to other Web-enabled panels • Add and delete schedules • Search database for individual points • Create exceptions for existing schedules Page 2 of 6 Siemens Industry, Inc. EFTA_R1_00017741 EFTA01735387 Reporting User Interface Customization FM Sae 10 il l Isnstage English Data Rene:hate. w" Altai coat ulitek mem coot FAA CVC, OC5Cdor D•vre Fare Cool • Re:et to Default • Custom Welcome Page • Generate Point Log Report with multiple filters • User interface translatable to any browser- supported language Graphical Trend Display • Ability to customize font sizes and display colors Online Database Editing • Database Configuration o Add/ Modify/ Delete points o Add/ Modify! Delete trend definitions o Add/ Modify/ Delete Event Enrollment Objects o Add/ Modify/ Delete Notification Class Objects • Ability to view one or more trends on a single • Schedule display o Add/ Modify! Delete schedules • Ability to view raw data values and export to CSV file o Add/ Modify/ Delete Command Objects o Add! Modify! Delete Calendar Objects • Custom Program Editor o Add/ Modify/ Delete programs o View and clear program trace bits o View disabled, unresolved, and comment lines • FLN Devices o Add/ Modify/ Delete FLN Devices • Print trend graph to network printers o Set and Release TEC Initial values • User Account o Add! Modify/ Delete user accounts o Change user passwords Siemens Industry. Inc Page 3 of 6 EFTA_R1_00017742 EFTA01735388 Graphics Creation and Editing • Graphics configuration tool allows remote\ offline creation, modification, and deletion of graphics. • Library of predefined graphic backgrounds • Ability to import standard image formats (.png, .jpg, and, .gif) Page 4 of 6 Siemens Industry, Inc. EFTA_R1_00017743 EFTA01735389 network. Data from every controller that has the Web Field Panel Web Server Services license enabled will be automatically displayed. At least one PXC Compact 36 or PXC Modular controller with firmware 3.2.2 is required on each WEB Browser WEB Browser Pc 16/24 PXC 36 with Web Services Enabled with Web Services Enabled Li a PXC Modular with Web • Services Enabled I. BACnet MS/TP P1 FLN BACnet MS/TP/ P1 FLN ± I =MI Inlij Figure 1 Field Panel Web Server Siemens Industry. Inc Page 5 of 6 EFTA_R1_00017744 EFTA01735390 Specifications Supported BACnet Field Panels BACnet IP-based PXC Modular BACnet IP-based PXC Compact 16/24/36 Note: At least one PXC Modular or PXC 36 is required on each network Web Browser Internet Explorer 6.0 or later, or Firefox 3.6 or later with Adobe Flash Player Plug-in 10.1 or later is supported Any browser capable of running and displaying Adobe Flash Player Plug-in 10.1 or later is compatible. Ordering Information Description Part Number SSN Field Panel Web Services License LSM-FPWEB P55801-Y104 Field Panel Graphic Editor 571-214 555801-Y139 Information in this document is based on specifications believed coned at the time of publication. The right is reserved to make changes as design improvements are introduced. APOGEE is a registered trademark of Siemens Industry. Inc. 2010 Siemens Industry. Inc. Siemens Industry. Inc. Country of Origin: US 1000 Deerfield Parkway Page 6 of 6 Buffalo Grove, IL 60089-4513 EFTA_R1_00017745 EFTA01735391
ℹ️ Document Details
SHA-256
378030d83bda9d718bed92428753655a99da18f5cca592d6340e23c7d993c064
Bates Number
EFTA01735386
Dataset
DataSet-10
Document Type
document
Pages
6

Comments 0

Loading comments…
Link copied!