👁 1
💬 0
📄 Extracted Text (460 words)
Well B 50gpm Upgrade
Pump Upgrade 7,600.00
3 Phase Converter 5,000.00
Tough Shed 2,500.00
Electrical Relocation to
Shed and Well S 7,000.00
Well 4 Refurbishment
Metal Building $ 40,000.00
Permiting $ 500.00
Booster Pumps $ 38,000.00
10,000 Gallon Tank $ 10,000.00
Pipping 5,000.00
Electrical 25,000.00
Project Total 140,600.00
EFTA01172578
Water Distribution and D.evelopromit Plan
The proposed changes & upgrades to the Ranch's Water Distribution System are
recommended to maximize the Existing Well pumping capacities, storage capacities
& Permitted Water Rights, which total 83.5 AM
As of date Combined Well production levels are Estimated at 119 gpm
Combined Storage Capacity is 40,000 gallons
Reminder:
When calculating usage, the Ranch does not operate it's Well Fields 24/7 and the
irrigation season is approx. 8 mths of the year
Development Plan
Phasel
This is re_quiredto,meet Existing Demand
Add a 6" pipeline from Well 4, B & K storage tanks (15000 gallons) to RC.
This will increase pumping capacity to RC & Mli Reservoir without the initial need
to replace existing pump skid at Wells 4, B & K
Downsize the Well Pump at Well 6 from 75gpm to a 30gpm Pump, connect via 4"
pipeline to the Dakota storage tank (10.000 gallons) & pump skid
Downsizing the Well Pump is necessary due to the decreased pumping levels at
Well 6
Connecting Well 6 to Dakota storage & pumps will increase the Ranch's storage
capacity to 50.000 gallons.
Estimated Cost for Phase 1 is/36,966,13-_Revisecl cost now 27,678.91
This does not include trenching, which will be performed with Ranch equipment &
personnel or legal/administrative fees
Phase 2
This is required to meet 50% of permitted allotment under Permit E-7871
It will be necessary to have the infrastructure completed by Nov 1 2015 to meet
Beneficial Use requirements, under the Settlement Agreement for E-7871
There will be a need for Administrative changes to Well B's Permit
Increasing pumping capacity of Well B to SOgpm, this will give a combined Well
rapacity of 150 gpm
Increase storage capacity with a new 10.000 gallon [ant
New Well Controller, pump skid and power upgrade to deliver water to RC, MIL IN,
Lodge, Log Cabin & Ranch related uses
New storage Facility to house pump skids, storage & power. Similar to the Metal
Shed located at Dakota Well.
Breakout ground & irrigate under Permitted conditions for E-7871
Estimated Cost for Phase 2, TBA
This does not include Hydrology, Legal or Administrative Fees.
EFTA01172579
Phase 3
The Principle has elected to proceed with applying for the full 68 afa, under permit
E-7871.
Addition ground will need to be irrigated to achieve the 68 afa.
A New Well maybe required to replace the existing E-7871 Dakota Well
There will Administrative and Hydrology costs involved
The Estimated cost for Phase 3, TBA
EFTA01172580
ℹ️ Document Details
SHA-256
39b16bcd0e1f8cd7de9876a6c0c7e54572d2bc187657ac6e45396da5c7167b44
Bates Number
EFTA01172578
Dataset
DataSet-9
Type
document
Pages
3
💬 Comments 0