EFTA01203799
EFTA01203802 DataSet-9
EFTA01203805

EFTA01203802.pdf

DataSet-9 3 pages 920 words document
P17 P23 V11 V15 P21
Open PDF directly ↗ View extracted text
👁 1 💬 0
📄 Extracted Text (920 words)
ALLIED BUILDING ORDER 4 STEEL Project / Number Date BUILDINGS Little St James USVI 4/15/2015 PROJECT LOCATION City/Country CONTACT INFORMATION Daphne Wallace Little St James USVI PAW ft af s via Hn I'M Poet gar'. th. . 04, •.1.110. v./C/IM 4.. Ca No 14, a. ea."( e tot tar %Cu Pon %y/, Piinterinr• C ol, In ch tin 4114 ed,7 Clarions 5.o ANON MipOrt airen. lit r....th arr. veva, "%flan Dotk fel ha --- tee PAIOTAO CenWtI. %aftoath Both kat( nat. I,aard tat-all-and icra Compel. Sal Les St :int Copr•tr etrAt• /Ord. MI) Mir r.:.,011 Allied Steel Buildings 101 NE 3 , Avenue. Suite 300. Fort Lauderdale. FL 33301 . T: 001-95a-590-4955 F: 001-95a-903.7970 . www.alliedsteelbuildings.com EFTA01203802 A BUILDING ORDER ALLIED STEEL Protect / Number Date Building BUILDINGS Little St James USVI 4/15/2015 1 1 DIMENSIONS BUILDING CODE 2009 IBC DEFLECTIONS Width 40' 1150 MPH Wind Exposure RR B EW Columns U 120 Frame Horizontal 60 250' Ground snow [o Soil class ID EW Rafters U 180 Frame Vertical 180 Length Wall Girls U 90 Frame Seismic 50 Cave height 116' Live load 120 psf I Normal Collateral load enclosed Roof Purlins U 180 Frame Crane B 100 U 11/12 Occupancy Enclosure 60 60 Wall Panel Wind Framing Roo! PAO Seismic I Ss-117%, S1.40% Roof Panel U 60 FRAME TYPE Column Rafter Frame Shape Framing Finish a Tapered a Tapered ID Gable Primary ElConstant ❑Constant ❑ Single slope Secondary EISpecial ElSpecial DI Special Framed Openings Endwall Column Spacing Sidewall Bay Spacing LEW 2@20' 10@25' REW Interior Modules a Clear span ❑ Support column spacing 2@20' SECONDARY FRAMING BRACING LEW REW FSW 85W ROOF Xibrace Rigid Portal Special frame l frame Flush Offset Bypass LEW El 0 DI PEW Zee IZee Zee Zee Zee FSW El ❑ 01 BSW El ❑ DII ROOF PANEL Gauge WALL PANEL Gauge ENDWALL TYPE a PIM 26 a PBR 26 Post & beam Rigid frame Rigid frame expandable Special riStanding seam OAlbed architectural ritUA EI N/A LEW El CI ❑ O! n Other I 00thet REW a ROOF PANEL COLOR WALL PANEL COLOR FRAMED OPENINGS a GaNalume (Standard) Galvalume El SW, SNP (Standard) ❑ KYNAR O KYNAR ACCESSORIES ACCESSORIES NOTES 14 (3070) Root insulation Walk doors rs Thickness / R value 16 (14x14) Overhead doors Windows I TBD TBD Ventilation Wall insulation TOO Thickness / R value Day lighting I Gutters and downspouts Yes a N. El TBD Allied Steel Buildings . 101 NE 3" Avenue, Suite 300, Fort Lauderdale. FL 33301 T: 001-95a-590-4955 F: 001.95a-903.7970 . www.alliedsteelbuildings.com EFTA01203803 ALLIED BUILDING ORDER A STEEL BUILDINGS Project / Number Little St James USVI Date 4/15/2015 PROJECT NOTES Note: Price includes preliminary drawings and stamped certified drawings Note: Preliminary drawings will be sent within 48/72 hours for review Note: All necessary purlins, girts, nuts, bolts, & self drilling screws are included Note: Complete trim package included Note: Price includes freight to port in W.P.B. FL OPTIONS PRICING FOR INTERNATIONAL PROJECTS FULL PAYMENT IS REQUIRED PRIOR TO LOADING (US FUNDS ONLY). PRICE $103,470.00 CHECKS MADE PAYABLE TO ALLIED STEEL BUILDINGS, INC. Buyer agrees to pay the balance of the complete price by money order or certified check upon delivery of the purchased FREIGHT See Notes goods and acknowl...Igni receipt of a completed copy of this purchase order. MI out-of-continental US delwries must be paid in full prior to batting. a COD is not availabk. Under no circumstances is cash to be paid to the driver for TOTAL $103,470.00 balances owed on this buiking. The purchase order by Buyer above named to Seller shall constitute an agreement binding upon Seller only when accepted in writing by Sellers authorized representative. BUYER IS RESPONSIBLE FOR ALL APPLICABLE SALES TAX. DUTIES AND BROKER FEES. The Project Manager of Seller preparing this purchase INITIAL PAYMENT $10,000.00 order is not an officer of Seger and not authorized to accept this order of Buyer. Upon receipt of this order al the home office of Seller. K the order is accepted. the "Acceptance' copy will be returned to Buyer. duly signed by en FABRICATION PAYMENT $75,000.00 Authorized Representative. or if not accepted. the initial payment shall be returned to Buyer. Upon acceptance. Buyer shall not be entitled to a refund of the whole or any part of the initial payment tendered to the Project Manager of Seller. Unless delay is the result of Allied causes. delivery after the requested delivery date wil necessitate that any increases in the cost of steel. materials or freight will be passed onto Buyer. Buyer will receive immediate knowledge of the cost increase through a Change Order reflecting the new price as soon as same is received by Seger. Al that time. Buyer can then agree to the increase by signing the Change order or cancel the contract; but Buyer will be liable for ag work performed and parts ordered up to the date of the cancellation. THIS ORDER IS SUBJECT TO THE TERMS AND CONDITIONS ON THE FACE AND ATTACHED DOCUMENTS. Buyer hereby acknowledges receipt of a complete BALANCE $18,470.00 copy of this agreement and agrees to ag the terms herein contained and as set forth in the Terms and Conditions. Due to the volatility in steel and fuel costs. pricks; is valid for 30 days. —Taxes, if applicable. are not included. VIEW OUR TERMS AND CONDITIONS Mike Stock 4/15/2015 Name Representative Date ease• Date Authorized Representative Date Allied Steel Buildings . 101 NE r Avenue, Suite 300. Fort Lauderdale. FL 33301 . T: 00I-954390.4955 . F:001.954.903.7970 . www.alliedsteelbuildings.com EFTA01203804
ℹ️ Document Details
SHA-256
3d0c04d0c493e3b928cd8b6d4ad04b5316b2752b8bfe4e45ffdd570de77ab698
Bates Number
EFTA01203802
Dataset
DataSet-9
Document Type
document
Pages
3

Comments 0

Loading comments…
Link copied!