EFTA01079956
EFTA01079977 DataSet-9
EFTA01079980

EFTA01079977.pdf

DataSet-9 3 pages 464 words document
P23
Open PDF directly ↗ View extracted text
👁 1 💬 0
📄 Extracted Text (464 words)
ARISIX AIR CONDITIONING CORP. July 18, 2013 Richard Kahn HBRK Associates Inc. Re: supplemental/additional air conditioning Dear Rich: Arista Air Conditioning Corporation is pleased to submit our proposal for special air conditioning of the master bedroom and the gym as well as having additional capacity for future air handlers as follows: Arista Air Conditioning Corp. hereby proposes to furnish and install the following: Engineering: We will hire a professional licensed mechanical engineer to survey and prepare sealed mechanical drawings for this project, including expediting with the NYC Building Department. Equipment: One (1) Mitsubishi CitiMulti 10 ton R-series (simultaneously heating/cooling) condensing unit. Unit to be rigged to roof and set upon equipment supports. One (1) 2.5 or 3 ton Mitsubishi air handling unit to be installed in the electrical closet adjacent to the master bedroom. One (1) 2.5 or 3 ton Mitsubishi air handling unit to be installed in closet of gymnasium. All required ductwork to install a supply diffuser in the cove in the crown molding of the bedroom. on the wall adjacent to electrical closet. ( owner to provide services of general contractor to make openings required and to re-plaster and paint same.) Sheetmetal ductwork in gym area to connect unit to existing supply diffuser over closet door. Install new thermostats for each air handler with remote temperature sensors if required. Prepare wiring diagram for your electrician to power up new condensing unit and air handlers. TNI NT TRI-STATE INDUSTRY LEADER IN AI CONDITIONING HEATING REFRIGERATION 38.26 TENTH STREET. LONG ISLAND CITY, NY 11101 • 'F EFTA01079977 All refrigerant piping from rooftop condensing unit to branch controller, then from branch controller to the two air handlers for the bedroom and gym. We will leave spare parts for future air handlers. System to be evacuated and charged with refrigerant. Units will be started up and operation explained to staff. We will perform controlled inspection for New York City Building Department. Total Quoted Price $ 97,925.00 • Work excluded: cutting, patching, painting and decorating. Roofing. Overtime. Power wiring. Structural steel if required. Our price is based is based upon a Capital Improvement and therefore includes all sales tax for material and equipment purchased for this project. There is a one year warranty on all labor and materials provided by Arista Air Conditioning Corporation and a five year warranty on the compressor provided by the manufacturer. If you have any questions, please feel free to contact us. Re ctfully submitted, Aria Conditioning Corporation I tanley P. Berger Chief Executive Officer • if we can have your rigger who is putting your water tower on the roof, put the condensing unit up at the same time. There would be a credit to you of $6,200.00 Accepted: Date: Terms: 1/3 upon signing Balance based on requisitions. EFTA01079978 EFTA01079979
ℹ️ Document Details
SHA-256
4b19d4cc65048501a60703e4248ca87a7a36e573fcb0f7da56599124b1534055
Bates Number
EFTA01079977
Dataset
DataSet-9
Document Type
document
Pages
3

Comments 0

Loading comments…
Link copied!