EFTA01837903
EFTA01837906 DataSet-10
EFTA01837911

EFTA01837906.pdf

DataSet-10 5 pages 584 words document
P17 P23 V16 V11 P19
Open PDF directly ↗ View extracted text
👁 1 💬 0
📄 Extracted Text (584 words)
To: Warwick Wic Cc: Gary Kerney Tom Sze [email protected]©gmail.com] From: Gary Kerney Sent: Wed 2/23/2011 7:35:33 PM Subject: Re: flagpole pool I was in physical therapy when you called ,any time tomorrow ok Sent from my iPhone On Feb 23, 2011, at 3:10 PM, "Warwick Wicksman" ‹ > wrote: Gary, Please let me know when we can speak about this more. I am concerned about just drawing something up, and having it built, with no real "design". I do not recommend building the pool house with no relationship to the design of the adjacent cabana structures. This will be pretty visible from above when Jeffrey flies in, and from the sea, and it needs to look right. I am available today until 12 LA time, or 2-4. Also tomorrow after 10am LA time. Thanks, Warwick Warwick Wicksman, AIA Princi al Gensler 2500 Broadway Suite 300 Santa Monica, California 90404 USA Into://www.Genslencom Click here to view Genslees 2010 Annual Report EFTA_R1_00219692 EFTA01837906 From: Warwick Wicksman Sen • W n F r 2 11 7:22 AM To: • Tom Sze Cc: leevacationOgmail.cornI; Subject: Re: flagpole pool I'll get you a proposal for plans sections and elevations today. Thanks, Warwick Wicksman Principal Sent from my BlackBerry Device. From: Gary Kerney ‹ > To: Warwick Wicksman; Tom Sze Cc: Jeffrey Epstein <ieevacationeomail.com>; William Rowles Sent: Wed Feb 23 07:20:27 2011 Subject: RE: flagpole pool Warwick It is a very simple building,and I gave you the design outline,) will do structuals here and we are using trusses,' would think you can get me a set of drawings in a couple days. Please call me Gary From: Warwick Wicksman [mailto Sent: Tue 2/22/2011 8:13 PM To: Gary Kerney; Tom Sze Cc: Jeffrey Epstein; William Rowles; Subject: RE: flagpole pool Gary, EFTA_R1_00219693 EFTA01837907 I got the sketches you sent, and attached is an updated plan sketch based on the new comments. But I am confused about what you arc asking us to provide. Our proposal was for conceptual design. It sounds like you are jumping from that to permit drawings in one week. Is that what you now need? And who is engineering the building, including the slab and foundations? Thanks, Warwick Warwick Wicksman, AIA Princi al Gensler 2500 Broadway Suite 300 Santa Monica. California 90404 USA htio;liwuw.Genski.com Click here to view Genslees 2010 Annual Report. From: Gary Kerney [mailso Sent: Saturday, February 19, 2011 7:09 AM To: Warwick Wicksman; Tom Szc Cc: Jeffrey Epstein: William Rowles- Subject: flagpole pool Wawick Specifications for construction development drawings.) need a quick turn around ,can form slab next week. Revised bath and kitchen programs attached Revised site plan attached BUILDING EFTA_R1_00219694 EFTA01837908 block structure 10' ceiling plaster finish in and out truss roof insulated and corr.metal roofing same as main compound crown molding and copper gutter same as main compound roll down hurricane shutters on 8' sliding glass doors(jeffrey mirrored?) mechinacial awnning over sliding door all other doors slabs INTERIOR floors stained concrete floors manufactured kitchen cabinets 30" refrigerator 30"range Ice maker dbl. sink bath to be ceramic tile floor and shower(small I "+-) wood vanity top,with vessel sink Grope shower fixtures all other American Standerd or eq. corner sconces in livingroom recess can liting all liting on dimmers all base wall outlets to be 1/2 switched POOL EFTA_R1_00219695 EFTA01837909 current thinking to reflect on next generation of image review 10x30 shade structure one each side 2x2 plaster col's 9' high 10" thick solid top ( 2' overhang?) ceiling cans,col. sconces,ceiling fans EFTA_R1_00219696 EFTA01837910
ℹ️ Document Details
SHA-256
609ecba45078e90e7b462e1b4a46cf7784a0210a8adeb433c6f0119b916a2a36
Bates Number
EFTA01837906
Dataset
DataSet-10
Document Type
document
Pages
5

Comments 0

Loading comments…
Link copied!