From: ZM
To: "Jeffrey E." <[email protected]>
Cc: Richard Kahn ..tj ann rodriquez
Subject: Re:
Date: Tue, 14 Mar 2017 19:32:41 +0000
No to water Softener
Yes to new HP Pump
Yes to reprogramming PLC
Incorrect backwashing procedure and no pre treatment have fouled membranes and damaged HP Pump
Post treatment of water needs to calibrated i.e. Sulphuric acid and Calcium carbonate injection
Patrick believes the product water is High in ph, but low alkalinity and is ionically imbalanced and could be
eating away Cistern Walls, hence white residue on fixtures
Once Plant is back online after service flush entire system could be 3 to 4 days
Take new water samples at RO Product ,cistern and main compound and send state side Lab
Establish a 1/4 maintenance program
Sent from my iPhone
On Mar 14, 2017, at 12:57 PM, jeffrey E. <[email protected]> wrote:
Patrick advice guides ro
please note
The information contained in this communication is
confidential, may be attorney-client privileged, may
constitute inside information, and is intended only for
the use of the addressee. It is the property of
JEE
Unauthorized use, disclosure or copying of this
communication or any part thereof is strictly prohibited
and may be unlawful. If you have received this
communication in error, please notify us immediately by
return e-mail or by e-mail to jeevacation®gmail.com, and
destroy this communication and all copies thereof,
including all attachments. copyright -all rights reserved
EFTA00645843
ℹ️ Document Details
SHA-256
7c37f7eb2e08f0c1b421cd5e2438292d40a849f7850c084ca4f9341bdbbcbd27
Bates Number
EFTA00645843
Dataset
DataSet-9
Type
document
Pages
1
💬 Comments 0