CARETAKER'S COTTAGE HURRICANE REPAIRS & ADDITION a .1.4= 41 OSC H U utKlcH HI rn . LTE I,1O PLANNINd GREAT ST. JAMES - NO.6A REDHOOK QUARTER ST. THOMAS, U.S. VIRGIN ISLANDS Elaettute Damn &ado PO &a 303190 St Thomas. V10(1803 4142Kowers Gads St Thomas. V10(1802 SUMMARY FOR PROPOSED ACTIVITY INDEX OF DRAWINGS GREAT ST. JAMES A. PURPOSE OF PROJECT: HURRICANE REPAIRS AND ADDITION TO G100 COVER SHEET AND LOCATION MAP NO 6A REDHOOK QUARTER EXISTING CARETAKER'S COTTAGE. DRIVEWAY AND PARKING U S. VIRGIN GLANDS AREAS. C101 SITE PLAN This document and the designs contained C102 ENLARGED SITE PLAN B. PRESENCE AND LOCATION OF ANY CRITICAL AREAS: herein are the sole property of Boschulle C200 SITE DETAILS Design Studio and shall be returned upon NONE NOTED. R101 request. This document may not be EXISTING PLAN C. PROPOSED METHOD OF LAND CLEARING: MINIMAL 8201 reproduced or coped in whole or in pan EXISTING ELEVATIONS without the written permission of EXCAVATION AT FOOTINGS. UTILIZING INDUSTRY STANDARD R202 EXISTING ELEVATIONS Boschulle Design Studio. Neither this EARTH-MOVING EQUIPMENT. ADIO1 DEMOLITION PLAN document nor any portion thereof may A101 PROPOSED FLOOR PLAN be used on any other project. D. PROVISIONS TO PRESERVE TOPSOIL AND LIMIT SITE A102 ARCHITECTURAL ROOF PLAN Unauthorized use shall invite a claim for ST. THOMAS DISTURBANCE: SEE SHEET C101. A201 ELEVATIONS compensation. The use by any person or A202 ELEVATIONS ST. JOHN firm of this document or any part E. EROSION AND SEDIMENTATION CONTROL DEVICES: SEE A301 SECTIONS thereof shall not in anyway subject SHEET C 101. A400 SCHEDULES Boschulte Design Studio to any cost or ASOI DETAILS damages for any error or omission F. SCHEDULE FOR EARTH CHANGING ACTIVITIES AND AS02 DETAILS contained therein. This drawing may not IMPLEMENTATION OF EROSIONSEDIMENT CONTROL AS03 ROOF DETAILS MEASURES: SEE SHEET C101 be used for the purposes of contracting • A901 PERSPECTIVES or construction without a stamped. A902 PERSPECTIVES signed. and dated Release Authorization G. MAINTENANCE OF EROSION AND SEDIMENT CONTROL MEASURES: SEE SHEET C101 in the He block of this Drawing. S100 FOUNDATION PLAN SIOI PROPOSED SLAB PLAN H. STORMWATER MANAGEMENT: EXISTING NATURAL SITE S201 ROOF FRAMING PLAN DRAINAGE AS SHOWN. E100 ELECTRICAL NOTES I. MAINTENANCE SCHEDULE FOR STORMWATER FACILITIES: EIOI PROPOSED ELECTRICAL PLAN NOT APPLICABLE. SITE VICINITY MAP P100 PLUMBING NOTES J. METHOD OF SEWAGE DISPOSAL: P101 PROPOSED PLUMBING PLAN GREAT ST. JA/4ES EXISTING ON-SITE PACKAGED WASTE DISPOSAL SYSTEM. NO 646 REDHCOK °DARTER U.S DEIGN ISLANDS ...' eg• A 8 ''. : . . le JEFFREY % a GENERAL NOTES e 13031)1ULTE * I. PROJECT IDENTIFICATION: CARETAKERS COTTAGE HURRICANE REPAIRS AND ADDITION 687A * : 4.0 ' .... ..KA. 2. PROJECT ADDRESS: PARCELS NO. A-REM. 8 A-2 GREAT ST. JAMES ISLAND NO. 6A RED HOOK OTR.. ST. THOMAS. VI l eaill 1ST!'' ...f.......... • 3. ARCHITECT: BOSCHULTE DESIGN STUDIO. PO BOX 303190. ST. THOMAS. U.S.V.I. 00802 4. KEEP ACCESS EASEMENTS. DRIVEWAYS. AND ENTRANCES SERVING PREMISES AND ADJACENT PROPERTIES CLEAR Ml Casensaion Os. AND AVAILABLE TO OWNER AND EMERGENCY VEHICLES AT ALL TIMES. DO NOT USE THESE AREAS FOR PARKING OR STORAGE OF MATERIALS. S. COORDINATE. SCHEDULE. AND APPROVE PERMANENT AND TEMPORARY UTILITIES. INCLUDING THOSE NECESSARY TO MAKE CONNECTIONS FOR TEMPORARY SERVICES. 6. DO NOT DISTURB PORTIONS OF THE SITE BEYOND AREAS IN WHICH THE WORK IS INDICATED. 7. REMOVE WASTE MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN A LANDFILL OR INCINERATOR ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 8. ALL WORK DONE SHALL COMPLY WITH THE LATEST EDITION OF THE VIRGIN ISLANDS BUILDING CODE. 9. JOB SITE VISITS BY THE OWNER OR ARCHITECT DO NOT CONSTITUTE AN OFFICIAL INSPECTION UNLESS SPECIFICALLY REQUESTED BY THE CONTRACTOR. 10. THE ARCHITECT SHALL BE NOTIFIED A MINIMUM OF 48 HOURS PRIOR TO START OF CONSTRUCTION BY THE CONTRACTOR. CARETAKER'S 11. DEVIATION FROM THE CONSTRUCTION DOCUMENTS WITHOUT PRIOR WRITTEN CONSENT OF THE ARCHITECT MAY BE CAUSE FOR THE WORK TO BE REJECTED BY THE ARCHITECT. THE ARCHITECT SHALL NOT BE HELD LIABLE FOR ANY COTTAGE DAMAGES OR INJURIES WHICH MAY OCCUR DUE TO ANY UNAPPROVED DEVIATION FROM THE CONSTRUCTION DOCUMENTS. HURRICANE REPAIRS AND ADDITION PARCEL NO. A-REMAINDER 8 A-2 GREAT ST. JAMES ISLAND NO. 6A RED HOOK OTR. ST. THOMAS. U.S. VIRGIN ISLANDS COVER SHEET Purlrambai 2019.001.01 owe 03-27-2019 WOW by BJS one:hear JIB SITE LOCATION MAP 7 ISSUED FOR BIDDING 03-27-2019 G100 Seale r . 1-0 EFTA00798250 sin SIT? aits......c> a ng sfis-a* )e 4r LONG j4 BAR 0 4.-1)- C= = I 4, 1, 010 . 0 .eCT itt '.,(9.09% Pt 4...00 SEDIMENT SILT SCREEN ATTACHED TO BARS ROCK BALLAST *:°: Z.Z°28 GRADE LINE Banta@ Dosn SAS, tic MIN. EMBEDMENT PO Nu 303190 SI. Thom" VI 00031 INTO EARTH 41-42K0Ws Gee, Si norm". %acme Phr" e^Tall 2 TEMPORARY SILT FENCE This document and the designs contained herein are the sole property of Boschulte Design Studio and shall be returned upon reouesl. This document may not be reproduced or copied in whole Or in pad without the written permission of Boschulte Design Studio. Neither thiS downed nor any portion thereof may be used on any other project. Unauthorized use shall invite a claim fix compensation. The use by any parson or firm of this document or any part Wit thereof shall not In anyway subject -- ----1-M-c;-) Boschulte Design Studio to any cost or damages for any error cr. omission Intik kk\ -- contained therein. This drawing may not be used for the purposes of contracting or construction ‘rithout a stamped. ,00\4111\e- \ple t Sired. and dated Release Authorization P' in the title block of this Drawing. 401.5patviiwit4 if:2 II er iir ctasi,47_rs siNtIL -W- -H t..,,,_......._,H ogit i _•----,--- it; \ Th t- ,-11;:4_, F,.....: t0 •..***,00 AR''. awl .441i11 / 00 .7/4,.... 14 2 1/ , #i, — se . JEFR1EY # , 54 ....../..ilk * 0\t 'Win ) sly;. 9K LCCATIM 0......istw "•;.friiio talteDTS (Oita NOTE: SEE SHEET S. ISS0o. OS C102 FOR ENLARGED SITE SITE PLAN Li1 1" = 200' ED CARETAKER'S COTTAGE HURRICANE REPAIRS AND ADDITION PARCEL NO. A-REMAINDER & A-2 GREAT ST. JAMES ISLAND NO. SA REDHOOK OTR. ST. THOMAS. U.S. VIRGIN ISLANDS SITE PLAN Pionlintel 2019001.01 owe 03-27-2019 Drai % by J7B CPSPM by JTB C 1 0 1 Sib AS SHOWN EFTA00798251 • • e t BOSCHULTE 0 r =. 'I, ., y 0 I/ I 0 Pt 4.../.14 in ' ral. (9.0% ♦ % EXISTING SWIMMING POOL WITH DECK (NOT IN • CONTRACT) Scnoxilie Noon Siitio PO Sox 303190 SI Thom" v100011 41-42Konoet Geth SI. Those. VIOIXO2 Diane (31411»-23T5 • boornothattraritys This document and the designs contained EXIST. DIRT herein are the sole property of Boschulte • Design Studio and shall be returned upon • • PATHS TYP. reouesi. This document may not be • ♦ reproduced or copied in whole Or in pad • • • without the written permission of • • • • Boschulte Design Studio. Neither thiS • ♦ • • • document nor any portion thereof may • • be used on any other project. EXISTING ONE7STORY • • Unauthorized use shall mete a claim fix ' EXISTING SOLAR ARRAY • • • LIVING •-• compensation. The use by any person or (NOT ehl CONTRACT) ♦ • ROOM/KITCHEN/DECK • \ arm of this document or any part • • • thereof shall not In anyway subject • .‘• • • EXISTING OLIANSET ♦~ •• .... IIIP NO MS IN IIII. Boschulte Design Studio to any cost or • P
ℹ️ Document Details
SHA-256
844c9eaf21b9d01e13f5573467cbe363d19befd929e1fbf9c8f5b681ca127149
Bates Number
EFTA00798250
Dataset
DataSet-9
Document Type
document
Pages
24

Comments 0

Loading comments…
Link copied!