Service Request #24975 Raid just crashed Status: FBOP Assigned Customer: FBOP MCC New York MS0109 (130104.001) Priority: P3 (Next Day) Contact: Type: Service Contract Assigned To: Service Location: Main Location 150 PARK ROW NEW YORK, NY 10007 Date Created: Aug 8, 2019 Bill To: FBOP MCC New Yodc MS0109 (130104.001) 150 PARK ROW Next Appt: NEW YORK, NY 10007 POIt Additional Information & Custom Fields: Is this a emergency request Yes. You must call 844-802-0188 Is the system in question under any warranty: What is the system in question : When was the problem first Today discovered: PO Number: Who reported the problem initally: Is this a consistent problem or CONSISTENT intermittent: Is this problem effecting all users: YES Is there power to the device in YES question: Do you have a spare device on Unknown site: Can you send a picture of the NO device: Has any work been done in the NO area involved: Can you describe what is or Is not recording happening: Material Required For Request: PHONE SUPPORT Who Requested the service call : Detailed Description: Raid is showing 2 "Ws on the display. is going to get new drives from computer services for the raid and replace them in the moming. Schedule EFTA00117584 When Assigned To Comment Aug 6. 16. 2019, all- will be working on this. Get a case started with Ciognity. day Equipment - No Equipment Comments Comment by on Aug 14. 2019, 8:02 PM PRIVAT called us on Thursday August 8th stating that he had 2 bad drives on his raid unit of the NICE Vision Pro Unit NVR. We advised him to get replacement drives. Once they are replaced they should start to initialize to become available for the raid array. did not have drives readily available. He checked with his local CSM to see if they had any spare replacement drives. Once he located replacement drives on Friday August 9th. he did not have access to the DVR room to replace them. He called Signet for phone support on Saturday August 10th when he gained access to the DVR room. He attempted to replace the drives and they started to rebuild. During the rebuildprocess of the drives. the drives were required to be taken out of the raid on DVR 2. Once the drives are removed without proper shutdown of the recorder, the video database becomes corrupted. Typically, any time the raid on a raid 5 configuration loses 2 drives, the raid needs to be rebuilt and all data is wiped from the raid. Comment by on Aug 8. 2019, 3:38 PM [PRIVATE] Him Unable to locate anything official. The basic steps are as following: 1. Set the raid level to none, and save. It will restarted with all drives being J. (Replace any faulty drives) 2. Set the raid level to 5 and save. It will restart and being an initialization. The password is 1111 (if!recall correctly). Once the raid is created, you'll need to restart windows and create the proper partitions.fi t keep looking but that should get you going. Best regards, Senior Support Engineer (1) (M) + www.gognify.com CUSTOMER SUPPORT CONTACTS USA Toll Free +1-866-8954607 USA +1-201-377-3408 UK +44-203-1501-393 UK Toll Free +44-800- 0488305 Israel +972-73-394-7900 France +33-170-70-0066 support©Qogni6<com German +49-3419-288-035 Singapore +85-3163-3144 India +91-117-1279-047 Hong Kong +852-5808-6118 China +86-10-5357-3270 From: < Sent: Tuesday, February 26, 2019 14:35 To: Support <Support©gognify.com> Sub : RE: PRO UNIT RAID REBUILD DOCUMENTATION REQUEST Anything you have on Pro Unit documentation would be appreciated. Senior Customer Su Technician SigNet Technologies j Convergint Federal Solutions 12300 Kiln Ct Suite E, Beltsville, MD 20705 Office. I Mobile. I Direct: Asst nment Created by on Aug 8, 2019, 3:36 PM The assignment on Aug 8 - 16, all-day for and has been created. I 111, will be working on this. Get a case started with Oognify. Details - No Detail Items EFTA00117585
ℹ️ Document Details
SHA-256
84627e74d54341a123256b0ab843c9d132820066356c98acdfada73a227a048c
Bates Number
EFTA00117584
Dataset
DataSet-9
Document Type
document
Pages
2

Comments 0

Loading comments…
Link copied!