EFTA01454620
EFTA01454621 DataSet-10
EFTA01454622

EFTA01454621.pdf

DataSet-10 1 page 542 words document
P17 V16 V15 D6
Open PDF directly ↗ View extracted text
👁 1 💬 0
📄 Extracted Text (542 words)
RRP72 - Southern Financial Team Experience Certain Team members have advised Deutsche Bank with respect to over 800 non-ESA energy efficiency retrofit projects involving more than 175 Deutsche Bank-occupied buildings' ft of Completed Projects3 Replacement of existing boilers with high efficiency units. Includes boiler plant pumping, piping, as well as controls retrofits and Boiler Plant Improvements 4 replacements. Chiller Plant Improvements Chiller retrofits or replacements. Includes chiller plant pumping, piping, as well as controls retrofits and replacements. 17 Comprehensive package of air conditioning and heat pump unit replacement. Addressed elements can include HVAC damper repair Heating, Ventilation, and Air and replacement; cooling tower retrofits or replacements; outside air economizers; air-to-air heat recovery; and variable air volume 40 Conditioning (HVAC) retrofits. Chilled Water, Hot Water, and Repair and replacement of hot water, chilled water and steam distribution systems. 7 Steam Distribution Systems Building Automation Systems Upgrade or replacement of existing building automation system and install additional HVAC controls. 18 Electric Motors and Drives Motor replacement with high efficiency units and variable speed motors or drives replacements. 9 Lighting Improvements Interior and exterior lighting retrofits and replacements, occupancy sensor controls, LED retrofits, and day lighting controls. 213 Building Envelope Improvements Building insulation, weatherization, window replacements, reflective solar window tinting, cool roofs. 4 Renewable Energy Installation of solar hot water and photovoltaic units. 5 Energy and Utility Distribution Transformer or power distribution unit replacement and associated power factor correction. 13 Systems Low-flow faucets and showerheads, low-flow plumbing equipment, cooling tower and boiler makeup water controls, grey water and Water 57 rainwater recovery. Energy Cost Reduction Through Utility rate and tariff optimization combined with historical bill and meter auditing. 5 Rate Adjustments Optimize recommissioning schedules, set points, and process controls. Test and repair control devices. Introduced monitored or Retro Commissioning 351 enhanced commissioning. Advanced Metering Systems Meter and report tenant energy consumption. Add meters to ensure tenant billing accuracy. 2 Appliance/Plug-Load Reductions Replace refrigeration and kitchen appliances, vending machine controls, plug timers and controls with Energy Star^ products. 17 Other Green building refurbishments, demand response programs, other. 69 Total: 831 ' The Team believes this prior retrofit experience. although different in certain important respects from the type of projects being targeted by the PartnersNp. is relevant in evaluating the Team's overall level of experience in the retrofit market Team members collaborated with. and were assisted by. certain employees of Deutsche Bank affiliates and certain third parties in completing these projects See Appendix F. Note 8 for additional important information :Based on U.S. Department of Energy. Federal Energy Management Program (FEMP) project categories Team members were also involved in an additional 229 projects not included in the table above because the Team concluded they did not invoke certain key elements associated with the Partnership's retrofit strategy These projects include new building fit-outs, real estate consolidations, data center optimization. desktop technology deployment, managed pnnt services. coffee Mater appliance upgrades. and 11.8monitor upgrades Covers 2009 - 2012 time period Does not include projects still in process or not yet validated as of year-end 2012 Deutsche Asset RREEF Retrofit Partners, L.P. For U.S. Person Clients of the U.S /Americas Key Client Partners Desk Only -• June 2014 CONFIDENTIAL - PURSUANT TO FED. R. CRIM. P. 6(e) DB-SDNY-0112866 CONFIDENTIAL SDNY_GM_00259050 EFTA01454621
ℹ️ Document Details
SHA-256
871bddf11ece29871e43d030dadd50f7e4de317cd1eed4e9318f566a9362a529
Bates Number
EFTA01454621
Dataset
DataSet-10
Document Type
document
Pages
1

Comments 0

Loading comments…
Link copied!