Sawyers is pleased to present to you the following proposal for upgrading the current Fire Alann
Systems for Mr. Epstein's Residence at 9 East 7I" Street in New York. Sawyers intends to replace both of
the existing Radionics Panels with a single new panel from Honeywell. The Honeywell panel will combine
both the Smoke Alarm Panel and the Sprinkler Alarm Panel into one coherent and integrated system. We
will utilize the points list provided, plus our own preliminary survey to map a list of Initiation Points to
trigger the existing Bell/Horn Strobe Loop. All Smoke, Duct, Heat or Carbon Monoxide Sensors will be
replaced with new models. As often as possible we will place the upgraded sensors at their existing location
and also try to ensure that a minimum of patching and/or painting will be required. Any patching or
painting will be by others.
Sawyers will be installing this system and will work with Vinny Buono from Lareto Electric to
ensure that the License Holder meets or exceeds all NYC code requirements. Sawyers will need to create
drawings for the implementation of this upgrade, for potential filing with the city of New York (Confirm if
you plan to file permits) and for "As Builts" upon the completion of the project for your own internal
records. If you have Architectural Prints of the Residence in a CAD format, it would be extremely helpful.
Our plan is to replace the Main Radionics Panel with a Honeywell Vista 128 BPT Panel. This
panel can support 128 zones (Your records show approximately 40 existing zones with approximately 60
Smokes, 8 Heats and 3 Gas Alarms) Sawyers will by and install Carbon Monoxide Detectors within Close
Proximity of all Bedrooms. We will use a combination of Polling Loop Modules combined with 2-wire
Smoke Detection Loop Modules to essentially replicate the current sensing topology. We can't put in Point
by Point Sensor ID modules as the building is wired with single strands of THHN wire. There is no "twist"
to these wires and using polling modules at each sensor would have questionable reliability.
Upon the completion of this project, all of the Detector Points would be replaced with new
sensors. We will be adding numerous Polling Modules, we will rewire and replace the Panels and clean up
the existing wiring. All Sprinkler Flows and Fire Pump and Tampers will be tied into the system and tested.
Any devices on the Sprinkler System itself that may need repairs or replacement are outside the scope of
this proposal. (Repairs provided by Sprinkler Contractor)
Please feel free to contact us with any concerns or questions.
Sincerely,
Tom Callahan
President, Sawyers
EFTA00287121
Fire Alarm System Requirements
(I) Honeywell Vista 128-BPT Alarm Panel $ 750
(6) Honeywell 4208U 8-Zone Hardwired Expansion Modules @ 150 $ 900
(This will replace all existing Radionics Expansion boards)
(12) Honeywell 4209U V-Plex Modules for 2-Wire & 4-Wire Smokes @ 150 $ 1,800
(2) Honeywell 6160RF English Text Keypad w/ RF Receivers @ 250 $ 500
(2) Resolution Technology RF Repeaters @ 250 $ 500
(I) Honeywell iGSMV Cellular Dialer (Required for Total Connect) $ 350
(60) Approximate number of Hardwired Smoke Detectors - installed @ 100 $ 6,000
System Sensor w/built in sounders — change out all detectors to new.
(8) Heat Detectors 4350 $ 400
(3) Gas Alarm Sensors @ 175 $ 525
(6) Honeywell 5800CO Wireless Carbon Monoxide Detectors @ 150 $ 900
(12) System Sensor D4120 Duct Detectors with new Smoke Sampling Tubes @ 275 $ 3,300
Sampling Tubes — DSTS Five Foot Sampling Tubes
(I) Miscellaneous Hardware, connectors, Conduit, etc. $ 1,000
(x) Fire Alarm Sounders/ Homs/Strobes — Reuse all Existing
(1) Sawyers' Labor for Panel Replacement, Panel Re-Wiring & Programming $ 9,580
• Includes Expansion Modules, Expansion Modules & Keypads
(I) Sawyers' Labor for all Field Device Replacements Including Polling Modules $ 12,525
(I) As-Built Drawings (AutoCAD files preferred) Documentation, & Training $ 5,750
(I) Sawyers' System Design Labor for the Panel Upgrade $ 3,500
Fire Alarm Upgrade Sub-Total $ 48,280
(I) Estimated Labor for Lareto Electric $ 7,500
Complete System Upgrade Total $ 55,780
• Central Station Monitoring is $ 52 / Month for Fire & Daily Test Timer
Central Station Monitoring for Total Connect (Smart Phone Interface) is $ 20 / Month
2012 Labor Rates:
Supervisor/Programmer: $ 85 / Hour
Field Technician: $ 75 / Hour
Helper: $ 65 / Hour
•Travel invoiced @ Half of the Hourly Rate