change the right hand anticipator
On Tue, Mar 29, 2016 at 11:11 PM, Larry Visoski <IIMI > wrote:
Jeffrey
From Pete:
Hi Larry,
I got the video and do see the 'tick' in the voltage on the right side for the precooler.
I didn't get to see the pressure changes from the video.
The broken wire found during the inspection was on the left precooler input sensor.
correct me I am wrong, but I believe that you told me that this was taken at a time that the issue was not felt,
and at .84M.
I don't have access to what we have changed and/or swapped from Westfield.
It has been documented on the aircraft database at TEB.
We have never been able to produce the issue, or obvious readings on the ground doing runs.
I don't expect to be able to reproduce them here either-
As a refresher-
The voltage reading is that going to the Torque motor-
The voltage then changes the amount of air supplied to the LP air valve- read on the PSI gauge (delayed
reaction).
Higher voltage causes higher pressure, which closes the valve, limiting the air going across the precooler.
The system is 'electrically controlled, pneumatically operated', and no voltage= no pressure= valve open.
Fail Safe to open.
More voltage, more pressure, valve closes more, less air over the precooler and then overboard from the lower
pylon.
From the video, it looks like the right side valve was being commanded to open and or close more every few
seconds.
That would change the airflow output under the pylon.
The voltage is generated by a Controller- basically a low tech computer.
Each one- left and right-are independent of each other, there is no cross talk.
Each has numerous functions, and inputs, to come up with the required output to the torque motor.
The torque motor, and valve only do what has been commanded by the controller.
The controller is sent information from-
Bleed air switch position- on/off
Wing heat on/off
Sensors- precooler input and output (400 degree output)
Anticipator- to judge the rate of change and prevent over/undershooting.
There are also other conditions that are monitored, I believe-
Engine running, not shutdown by fire handle, bleed overheat, etc.
EFTA01183920
The controller output voltage is what is being read on the gauge.
Many components have been swapped, or replaced.
I don't think that we will be able to pinpoint any items while here.
My next recommendation is to swap the torque motors-
If one is sticking (they only move internally to vary the airflow supply to the valves through 1/4 inch lines,
like the one we replaced),
it could cause the controller to over respond first one way, then the other.
There are no external indications of the unit position.
The ticking of the voltage seen in the video?
The units only control supply air to the precooler LP air valves.
They are about the size of the a baseball, easily held in your hand.
Both are located in the tail compartment.
Regards,
Pete
Sent from my iPhone
please note
The information contained in this communication is
confidential, may be attorney-client privileged, may
constitute inside information, and is intended only for
the use of the addressee. It is the property of
JEE
Unauthorized use, disclosure or copying of this
communication or any part thereof is strictly prohibited
and may be unlawful. If you have received this
communication in error, please notify us immediately by
return e-mail or by e-mail to [email protected], and
destroy this communication and all copies thereof,
including all attachments. copyright -all rights reserved
EFTA01183921
ℹ️ Document Details
SHA-256
a756517e93a1f935adb3c4a151552ffdbaf9ac114007d51e17c099a9d08c32da
Bates Number
EFTA01183920
Dataset
DataSet-9
Document Type
document
Pages
2
Comments 0