EFTA01057539.pdf

DataSet-9 5 pages 478 words document
👁 1 💬 0
📄 Extracted Text (478 words)
From: "jeffrey E." <[email protected]> To: Larry Visoski <1.a> Subject: Re: ICA Wifi update Date: Wed, 16 May 2018 19:32:35 +0000 Inline-Images: image006.jpg; image005.jpg; image004.jpg Gulfstream should pay On Wed, May 16, 2018 at 9:25 PM Larry Visoski c wrote: Jeffrey We got the ICA Wifi to work for about 10 minutes near the end of the day, appears we have a connectivity issue between the MODman located in the baggage compartment which directs information to the ICANDu which is located in the tail section, the MODMan tells the KANdo where to aim the antenna on the tail toward the satellites., in simple terms it's an ethernet connection between the two boxes. Honeywell admitted their early installations had wire issues, they experienced on their own GV test aircraft, Gulfstream in Westfield / Scott Kellogg in avionics fixed the HoneyWell GV and is very familiar with this repair, I will make sure Westfield has the parts and it should only take approximately 1 day to repair., Appears our antenna is fine., If you agree I can take the aircraft to Westfield for repair? See message from James Lee the senior Honeywell tech-support, extremely sharp person., very helpful today! Hi Larry, per our conversation, my recommendation is to redo the Ethernet quadrax termination between Modman and KANDU. This is very similar to other G550 that we have worked on last fall. The issue you're having with the heartbeat failure (MM failing to receive heartbeat check) and 34% MM to KANDU packet drop resembles what we saw. Those units also worked intermittently at times. copying Jorge, Patrick, and Jonathan from Gulfstream Savannah support engineering group as well as Scott in Westfield (he will know which parts you need) who has worked on fixing the couple of quadrax issues on two Honeywell G550s. My recommendation is to first revisit the installation drawing and check if quadrax is designed incorrectly. If so, update the drawing (Gulfstream). Then, correct the quadrax termination as required to fix the intermittent ping between MM and KANDU. Below is my note from last October working on Honeywell G550. FYI, I drew out the quadrax per the current dwg. EFTA01057539 Ebmagel .JPG G650 EFTA01057540 image3.JPG G550 EFTA01057541 image2.JPG Best Regards, James Y. Lee Senior Technical Support Engineer - SATCOM Customer & Product Support EFTA01057542 Honeywell I Aerospace Sent from my iPhone please note The information contained in this communication is confidential, may be attorney-client privileged, may constitute inside information, and is intended only for the use of the addressee. It is the property of JEE Unauthorized use, disclosure or copying of this communication or any part thereof is strictly prohibited and may be unlawful. If you have received this communication in error, please notify us immediately by return e-mail or by e-mail to [email protected], and destroy this communication and all copies thereof, including all attachments. copyright -all rights reserved EFTA01057543
ℹ️ Document Details
SHA-256
c2c83ac5967eb6c65dc8736ea8df6808e9ef1e6efe9430e13e612f90afc6d0b5
Bates Number
EFTA01057539
Dataset
DataSet-9
Type
document
Pages
5

Community Rating

Sign in to rate this document

📋 What Is This?

Loading…
Sign in to add a description

💬 Comments 0

Sign in to join the discussion
Loading comments…
Link copied!