EFTA01183402
EFTA01183405 DataSet-9
EFTA01183412

EFTA01183405.pdf

DataSet-9 7 pages 1,364 words document
P17 V16 P18 P19 V11
Open PDF directly ↗ View extracted text
👁 1 💬 0
📄 Extracted Text (1,364 words)
From: Ann Rodriquez alMil > To: Larry Visoski <1.a> Cc: Rich Kahn "jeffrey E." <[email protected]> Subject: Fwd: Helipad ground light Quote Date: Fri, 15 Apr 2016 17:38:08 +0000 Attachments: Crystal_Reports_-_Sales_Order_Printing.pdf; 2.5.3_HL-392.pdf Inline-Images: imagel.PNG; image2.PNG; image3.PNG; image4.PNG; image001.gif Hi Larry, Attached is another quote from Danny for the Helipad ground lights. Please review and advise. EFTA01183405 Page: 1 Quote Customer Number: 01.O0OTEVI Flight Light Inc. Quote Number: 0056528 2708 47th Avenue Quote Date: 4115/2016 Sacramento. CA 95822 Expires On: 5/15/2016 Phone: 916-399.2800 Fat 916-394-2809 Salesperson: keno Bores www.fligh0ight.corn Bill To: Ship To: PH.(340)227-5323 [email protected] Conarm To: Notes: Danny Vicars Ship VIA Terms BEST WAY Prepay by Check or Creck Card Item I Description U0M Ow Quoted Price Amount HL-392-Y50 EA 10.00 425.00 4.250.00 Heileck Inset Lint Yellow Anodized 120V 50W 7.2513C wilemale connector Boas and washers horded BA-725.5.2P1 EA 10 00 92.00 920.00 ease can 8 5"x 5- deep 1"twn.0180 Woround strap 2"Drain writing 7.2513C met lit Phwood (:Who Foe 392 Rooms Nat Order: 5.170.00 Freight at Customers Expense Freight: 0.00 Thank you for considering usll Sales Tax: 0.00 Please contact us Stith any questions. 5.170.00 Order Total: TOMS and conditions apply. All prices are in U.S. dollars. For Flight Light Warranty information: ^ terms.htmlinearranty EFTA01183406 Flight Light Inc. 2708 47th Are. Sacramento, California, U.S,A. 11L-392 95822-3806 LED or Halogen PH (916) 394-2800 1-2( (916) 394-2809 Helideck Semi-Flush TF (800) 806-3548 EM info@ Perimeter Inset Light Compliances • FAA AC 150/5390-28 Heliport Design Guide • US Army Aviation Lighting Manual TM 5-811-5. Figure 5-3 • Exceeds FAA Engineering Brief 87 Specifications • Transport Canada TPI4371. AGA 7.16 • ICAO Annex 14. Volume II • UK CAA CAP 437. Chapter 4. paragraph 3.1 (optional. please • UL 1598 Standard (only "LP" lamp is UL listed) specify at time of order) Applications Semi-flush perimeter light helps mark helipad touchdown and lift-off area (TLOF) and/or final approach and takeoff area (FATO) for metal helidecks and pavement heliports. Why Our IIL-392 is Better • Recessed, semi-flush mounted, allows for obstruction-free movement of equipment and personneL • Corrosion resistant anodized finish Custom color matching is amilahk suitable for marine environments and to meet )'our design specifications available in many different colors. • Light channel within .r (5mm) of grade. • Lightweight and robust aluminum • Color beam variations achieved by Marine Treated alloy construction. dichroic coating. optionalfinish for high • Drop into metal helideck and fasten • Exceeds L-861 photometric require- salt ensironments. with 6 bolts. ments when used as a medium inten- • Pressure test plug ensures moisture- sity white runway edge light. Visible/Infrared LED Option proof light cavity. • Lamp bypass options available. • Night Vision Goggle • Prism removal and replacement • 8" style: weight 4.65 lbs. (2.1kg). Car- (NVG) compatible. achieved without need for adhesives ton size: .23 cu. ft. (A)07 cu. meters); • Optical Specifications: or sealants 9" (d) x 9" (w) x 5" (h) (229mm (w) x - Infrared Output: • Pre-fonued optics simplify maintenance. 229mm (d) x 127rom (h)) • Exceeds SAE Aero- • Available in 12-24 VDC or 120 VAC space recommenda• versions LED Version tions for Landingrfaxi Lights • Cost-saving. energy-efficient LEDs. • Direct retrofit, drop in replacement. • Usable beam width: 55° to 12? Factory retrofits available for your • Power Consumption: vertical. 360* horizontal. existing halogen fixtures. AC input = 7.2VA: DC input = 4W. • Power adapter included. • Output wavelength: 850nm. Independent intensity testing has Visible Output: provided results which exceed FAA • Low maintenance - LED light source has 50.000 hour lifetime (50X longer • Exceeds ICAO requirements for Engineering Brief 87 specifications, than halogen). green LEDs (see photometric chart). Available for non-heliport applica- • Monochromatic output of LEDs is • Usable beam width: 30° vertical. tions such as architectural lighting. 360° horizontal more conspicuous than halogen. Specifications • Pilots prefer LED over halogen be- • Output wavelength: 530nm. • Anodization: Aluminum Fixtures, cause of increased visibility. • Electrical Specifications: machined stock 6061T6. Anodize Mil • With our Dimming Controller option. - Input voltage range: 100 to 240 VAC. 8625 Type III. 1 mil thick. the lights can be dimmed at night to • Input frequency: 50 or 60Hz. • Low profile: .81" (base can mounted). reduce glare - 3 brightness levels. - Input current: 40mA AC. 1.06" (helideck mounted). • LED can be used with 120V/240V. - Input power to the fixture: 10.8 VA. • Bolt circle: 7.25" 50Hz/60Hz power. - Fixture is internally grounded. Visit our web site: Data Sheet: HL-392 2.53 9/25/2015 Page 1 of 3 EFTA01183407 Flight Light Inc. LIGHT 2708 47th Ave. FLIGHT Sacramento, California, U.S.A. HL-392 95822-3806 LED or Halogen PH (916) 394-2800 FX (916) 394-2809 Helideck Semi-Flush TF (800) 806-3548 EM Perimeter Inset Light Common Replacement Parts I Body Casting (Std) - Anodized 2 Bottom Cover Casting 80-040206 to N/A Elkay Gland Set 4 Bottom Cover Gasket ...... _.......... 80-021114/5/6 27-4061T271 40- CD_ is 6 Prism Clamp 36-392-PLT 8 Bottom Cover Spinning Clamp 80.021311 15 Prism Clamp Gasket 80-021309 16 Prism Gasket 80-033090 18 White (Clear) Prism Dome 80-016080 ALT Green Prism Dome 80-019193 ALT .. Yellow Prism Dome 80-019181 ALT _Red Prism Dome ......_.......... 80-019182 ALT.. Blue Prism Dome 80.019190 20 50W 170V Reflector Lamp LA-008084 ALT LED Cluster 3)-XLX 24 21 120V/240V lamp holder 80-015057 22 Lamp Gasket 80.033077 23 Lamp Retaining Spring 80-032039 Photometric Comparison with 24 B-Type Male Lead (LED Only)_.... TRC-10518-I 14D02 ICAO Requirements 25 Pressure Test Plug 80-021256 Vertical Aogle Avg. Semler ICAO Spec ALT ..Schrader Tank Valve 80-021327 (Cd) (Cd) N/A...3-Pin Male Connector (Halogen) 80-013031 2 70.8 15 N/A...3-Conductor limak Connecter (Halogen) 80-012022 5 66.5 30 10 48.3 15 13 36.6 8 Ordering Codes 20 23.9 3 Fixture Output Lamps Custom Color' Compliance HL-392 G: Green (std)' 50: 50W. 120V' C: Green UK: UK CAI' 4376 II: Blue 52: SOW, 240V' B: Blue UL: UL L *Led' It Red LP: 120V/240V LED' MT: Marine Treated W: White LV: 12V LED' MG: Military Green Y: Yellow LVD: Dimming 12V LED' It: Red IR: Infrared= Y: Yellow (hard gold) 114392 Green is cuiteraly the tmonuncnded output color for behpon perimeter lights ' Gray anodized si the standard finish. Infrared can bc used in conmention anti cola LEDs GUM is the lammed output Cant Lamp option is not UL listed. Only 'it' lampoptioncan he UL Baal. Connector Color LED with white ickari prism Power adapter uniudod. 120V/210V. not included isit our web site: ss 2.5.3 Data Sheet: HL-392 Page 2 of 3 9/25/2015 EFTA01183408 Right Light Inc. 2708 47th Are. Sacramento, California, U.S.A. HL-392 95822-3806 LED or Halogen PH (916) 394-2800 FX 916) 394-2809 Helideck Semi-Flush TF (800) 806-3548 EM Perimeter Inset Light 06.55e:010 08.6254 '135° ■ of Top Ring 02.000 Oroin Hole in Bottom Flarge Flames 81.010[254mm) A A Notes: 1.) Grommeted Holes are placed 0 0' & 180' 2.) 2- Drain Hole is Placed in Bottom 3). One internal Strap [12X) 0.375 Drilled Thru Top 07.2501.010 Bolt Hole arc's Tap 3/8- - 16 O O (12x] 30' a onlinuous a .375 Watertight Weld Section x/x—.030 AA 01.688 .109 lAnimum .xx .010 of V-180' for .xxx...005 2x— r Conduit 5.000 Grommet 1.3 3 mi dimensions .109 in inches Continuous Minimum Wotert:gh• unless otherwise weld specified 2.000 Oran Flight Light Inc. • seranc. 9.000 I" . ion mon Ground 4 14 04 A IS I Strap(s] le 0044 ream re As Specified W‘k 5' Shallow Base (PiNBA•725.5.2P1) \ hll Hi] ‘..ch \Hi t : Data Sheet: HL-392 2.5.3 9/25/2015 Page 3 of 3 EFTA01183409 Find us on f Facebook Ann R. Begin forwarded message: From: danny <I > Date: April 15, 2016 at 1:08:44 PM AST To: Ann Rodriquez •cl Subject: Fwd: Quote Sent from my iPhone Begin forwarded message: From: loana Flores ctl Date: A ril 15 2016 at 12:52:50 PM AST To: " it Cc: Susan Slish Subject: FW: Quote Hello Mr. Vicars, Attached is the quote you requested and the data sheet. Feel free to contact me if there is anything else you need. Thank you. Best Regards, loana Flores Flight Light Inc Phone: 916-394-2800 Ext 231 Fax: 916-394-2809 Web: Please give us your feedback by clicking the link below EFTA01183410 EFTA01183411
ℹ️ Document Details
SHA-256
c93346c57363e8666d859c591a77529443497102fdcb1b58b0b50d4a54ff71f0
Bates Number
EFTA01183405
Dataset
DataSet-9
Document Type
document
Pages
7

Comments 0

Loading comments…
Link copied!