From: Jeffrey Epstein <[email protected]> To: Richard Kahn Subject: Re: 71st Street - Chiller/Tower Proposal Date: Fri, 15 Mar 2013 18:58:12 +0000 Do it On Friday, March 15, 2013, Richard Kahn wrote: Rich B and I both followed up this week (numerous phone calls) with Pierpont (other bidder on this job) whose original bid came in at 330,000. Their bid was missing Electrical and Protection which Rich B estimated to be approximately 20,000 - 30,000. Pierpont came to the house last week and was supposed to have new proposal this week. Neither of us received a return phone call nor revised bid to reflect additional costs. This lack of communication and follow through has left me very uncomfortable with this vendor. The other bid we received was from AD Winston (dated June 19th 2012) in the amount of 357,255. Rich B called ADW in Feb 2013 and asked them to update bid and lower price. They said that they have had price increases since June 2012 however in good faith they lowered bid by 5,000 to 352,255. This week when i spoke to ADW i asked for further price reductions. They reluctantly said they would lower their price to 350,000 however they could not go any lower. I also reviewed the scope of their work and wanted to highlight a few facts: a)Lead Time is 10-12 Weeks Work (start to finish) 3 Weeks If we send deposit by Monday we would be in position to begin job in middle of June 2013. b) Sales Tax will not be charged as we will fill out NYS Form ST-124 Certificate of Capital Improvement c) payment terms 113 acceptance of bid, 1/3 upon delivery and 1/3 upon completion There were two other items outside of this bid: I) Rich B will need to bring in Siemans to perform electrical control wiring which Rich B estimates cost to be approximately $8,000 2) Only extra not included in ADW Bid was the installation of a VFD (variable frequency drive) which varies the speed of the fans on the cooling tower as compared to standard feature of High Low and Off. Currently we do not have a VFD and ADW said the payback period of energy savings would be approximately 10 years. The cost for this extra is 22,656. Please advise if ok to proceed with AD Winston. Option 1 - ADW and no VFD 350,000 - 116,666.67 deposit required Option 2 - ADW and VFD 372,656 - 124,218.67 deposit required EFTA00956071 Richard Kahn HBRK Associates Inc. Begin forwarded message: From: Richard Barnett <I Date: Februa 28, 2013 1:29:57 PM EST To: Subject: FW: Revised Chiller/Tower Proposal Hi Rich as requested here is the revised proposal from ADW. From: To: Subject: Revised Chiller/Tower Proposal Date: Thu, 28 Feb 2013 12:25:44 -0500 Hi Richard, Attached please find revised proposal. Please note, that while reducing the price, A.D Winston will be receiving price increases from vendors and contractors. Thank You, Mike Michael Palladino Vice President A.D Winston Service Inc Email: Phon Fax: The information contained in this communication is confidential, may be attorney-client privileged, may constitute inside information, and is intended only for the use of the addressee. It is the property of Jeffrey Epstein Unauthorized use, disclosure or copying of this EFTA00956072 communication or any part thereof is strictly prohibited and may be unlawful. If you have received this communication in error, please notify us immediately by return e-mail or by e-mail to [email protected], and destroy this communication and all copies thereof, including all attachments. copyright -all rights reserved EFTA00956073
ℹ️ Document Details
SHA-256
c99d6697d6d79931cd5a80749963e2e924872b8d5777bf8324e7ca9b58e7ab25
Bates Number
EFTA00956071
Dataset
DataSet-9
Document Type
document
Pages
3

Comments 0

Loading comments…
Link copied!