METROPOLITAN TESTING AND BALANCING CORP. 22-14 124TH STREET COLLEGE POINT, N.Y. 11356 OFFICE (718) 747-5545 FAX (718) 747-5547 DATE: 5/21/13 VENTILATION TEST REPORT EPSTEIN RESIDENCE 9 EAST 71ST STREET NEW YORK, N.Y. 3RD FLOOR PREPARED FOR A.D. WINSTON SERVICECORP. 43-15 36"1 STREET L.I.C., N.Y. 11101 JOB NO. 4582 EFTA01107704 METROPOLITAN TESTING AND BALANCING CORP. Date 5/21/13 Page 1 of 3 Project 9 EAST 71ST STREET System No MASTER BEDROOM UNIT (MB UNIT1 Flood! ON el FLOOR (SERVES 3RD) AIR DISTRIBUTION TEST SHEET FAN MAKE MAGIC AIRF. RATED ACTUAL SIZE 120-BVW / BVX-A LINE VOLTS 208/3/60 208 7.4/7.4/7.4 (WITH AC-3 ON ) MOTOR HP 3 MOTOR AMPS 9.9 8.1/8.1(7.9 (WITH AC-3 OFF) RPM 1775 REQUIRED ACTUAL LW (Willi AL-3 UN) STATIC PRESSURE: FAN RPM N.A. 1283 (WMI AC-3 OFF) 2192 (WITH AC-3 ON) SUCTION SEE SP IN. w.O. SYSTEM CFM 2100 2783 (WITH AC-3 OFF) DISCHARGE PROFILE. IN WG Terminal Terminal Design Final Number Type Size Factor FPM CFM FPM CFM Static Pressure (in.w.g.) AC-3 ON PPLY Fr-MB SU MAIN DUCT 26X15 2.7 777 2100 812 2192 +2.0 AC-3 OFF PT-MB MAIN SUPPLY DUCT 26X15 2.7 777 2100 1031 2783 +3.0 AC-I OFF* ACCESS DOOR IDOWNSTPJAI REMOVED PT-MB SUPPLY MAIN DUCT 26X15 2.7 777 2100 1337 3610 +1.3 Remarks: EFTA01107705 METROPOLITAN TESTING AND BALANCING CORP. Date 5/21/11 Page 2 of 3 Project 9 EAST 71ST STREET System No MASTER BEDROOM UNIT (MB UNIT) Floor!! 3RD AIR DISTRIBUTION TEST SHEET Terminal Room Terminal _ Design Final Number Number Type Size Factor FPM CFM FPM CFM Remarks WITH AC-3 ON 1 SG 42X2 NA 291 2 SG 42X2 NA 263 3 SG 38X2 NA 299 4 FG 5'0" NA 740 5 FG 5'0" NA 745 TOTAL 2100 2338 WITH AC-3 OFF 1 SG 42X2 NA 349 2 SG 42X2 NA 322 3 SG 38X2 NA 349 4 FG 5'0" NA 900 5 FG Sr NA 890 TOTAL 2100 2810 Remarks: EFTA01107706 METROPOLITAN TESTING AND BALANCING CORP. Date 5/21/13 Page of 1 'roject Name 9 EAST 71ST STREET STATIC PRESSURE PROFILE o.a. dampers I mix. box •~7• g UNIT a b c d e f g h j •M5 UNIT -.88 X X X -1.0 X X X +2.0 ••MB UNIT -.30 X X X -.46 X X X +3.0 :marks *READINGS WITH AC-3 ON **READINGS WITH AC-3 OFF EFTA01107707 16x8 TOILET EXH. UP TO EF-8 550 CFM 24x5 DN. 16x6 UP 12x4 TAP 140 CFM EA TYP. FOR 2 12-Wx6-Hx3.- A.L. PLENUM -12x6 TYPICAL FOR 3,- I 16. 1Vx6-Hx4.-41. A.L. PLENUM 24x10 SUPPLY GRILLES 1 170 CFM 10x6 6 \ 18'Wx10-1-ix5.-0"L A.L.PLENUM 16x10 R.A. OPNG. TYPICAL FOR 2 ABOVE CLG. 500 12%8' TAP W/ C.O.D. - 325 TYPICAL FOR 2 10x6 UP 250 CFM UP TO GUEST SITTING RM -16x10 R.A. OPNG. ABOVE CLG. 500 CFM 28x10 18-Wx8"Hx4.-0'L A.L. PLENUM© 14-x6- TAp W/ CO D. - 290 CFM 28x10 R.A. OPGN. ABOVE CLG. 670 CFM x6 EFTA01107708
ℹ️ Document Details
SHA-256
d6c9f9cb03c25a232d56a75b5abec00a1f9070e9502f3138d3bde4f7a177ce46
Bates Number
EFTA01107704
Dataset
DataSet-9
Document Type
document
Pages
5

Comments 0

Loading comments…
Link copied!