To: Jevacationpeevacationqpgrnaitconl
From:
Sent: Mon 4/26/2010 10:24:59 PM
Subject: N722JE
New radar MFD installed functional checked good, waiting on Honeywell's report on
failed MFD's that have been installed on 750.
UPDATE April 26, 2010 18:000ver the last three days, all of the wiring connecting
to the MFRD has been checked for correct termination points. Meg-ohm meter checks
were performed. The wires were checked for proper voltages and grounds. No
anomalies have been found.
Based upon a conversation between customer representatives and Honeywell Senior
Field Service Engineer Greg Milton, MFRD S/N: 0448 was installed, configured and
tested. The system is currently operating normally.
Honeywell Contact Information
Gregory R. Milton
Senior Field Service Engineer
Honeywell Aerospace
Phone
Sent from my BlackBerry?) wireless handheld
EFTA_R1_01495004
EFTA02426223