Commercial & Industrial HVAC Systems • Complete Service Contracts • 24 Hour Emergency Service
43-15 36th Street Long Island City New York 11101
TEL 718.361.2811 FAX 7113.361• 5798
www.actwinstonservice.com
INSPECTION and MAINTENANCE AGREEMENT
a. d. winston service inc. proposes to furnish Planned Inspection, Maintenance, and
Emergency Services for the Equipment listed below located in the premises EPSTEIN
RESIDENCE 9 EAST 7181. STREET NEW YORK, NY 10021 starting Upon
Acceptance/Signature and extending for a period of one year from this date.
a.d. winston service inc. shall furnish all labor necessary to inspect equipment, grease and
oil as necessary, change filters and belts as needed. Replacement parts and materials
required to keep the equipment in good operating condition shall be installed at the rates and
prices that prevail at the time such repairs are made. Replacement parts, which are standard
truck stock, will be installed at the time of the service call. Repairs requiring non-stock parts
shall be quoted and approval given before repairs are performed unless the nature of the
emergency requires our immediate response (Replacement parts and materials, pick up and
delivery, and shop repairs are not included as part of this agreement).
a.d. winston service inc. shall provide Emergency Service as needed, between inspections,
during normal working hours. As a Planned Inspection, Maintenance, and Emergency
Service Customer, you shall receive Preferential Service over all other types of service
activity.
a.d. winston service inc. shall provide (6) (see page 6 for details) regularly scheduled
inspections of the equipment listed herein during the term of this agreement. This shall
include start-up preparation of equipment for the summer cooling season and shutdown or
changeover of equipment from summer to winter operation.
This agreement shall include service calls made during normal working hours,
between 8:00 am and 4:30 p.m., Monday through Friday, excluding holidays.
Emergency Service is available on a 24-hour basis, but the customer shall be required to pay
the charges based on our current labor rates and the prevailing overtime differential as
directed by our labor agreements. Overtime rates shall apply for portal-to-portal time for the
service mechanic on call. a.d. winston service inc. has mechanics on call 24 hours per day,
7 days per week. Emergency Service can be obtained by calling (718) 361- 2811, 24 hours a
day.
EFTA01125021
GENERAL
a.d. winston service inc. shall furnish Planned Inspection, Maintenance, and Emergency
Service until written notice of termination is given. This contract is subject to price revision
and/or cancellation on any anniversary date by written notice of either party at least 30 days
prior to such anniversary date. No refund of payment shall be made if contract is canceled
before the anniversary date.
a.d. winston service inc., assumes no liability whatsoever and is not liable for any work
performed or materials furnished by anyone other than a.d. winston service inc. and at our
option, we may declare this contract to be void if at any time during its term, services are
performed by anyone other than us in connection with all equipment covered by this
agreement. We shall not be responsible for the system design or its performance in
maintaining design conditions except for the failure of the equipment covered under the terms
of this agreement.
a.d. winston service inc., shall not be required to make any repairs or replace any parts
caused by the negligence or wrongful use of the owner or his agents, accidents, abuse, fire,
freezing, flood, failure of power or water supply, drainage, plumbing, strikes, acts of God, war,
requirements of governmental agencies in their enforcement of codes, items recommended
or required by insurance companies, government, state, municipal and/or other authorities,
building regulations, or union regulations. If the equipment requires the use of water, either
re-circulated or otherwise, we shall not be responsible for contamination of the water or
corrosion of the pipes for any reason whatsoever. Services rendered for any repairs due to
the items listed above shall be considered an extra to this agreement and shall be paid for by
the customer.
a.d. winston service inc. is not liable for any equipment controls, or systems not listed on
our equipment page.
a.d. winston service inc. shall carry Workmen's Compensation and Public Liability
Insurance during the term of this agreement.
a.d. winston service inc. shall perform the applicable maintenance procedures for the
equipment specified on the "EQUIPMENT LIST". The maintenance procedures are as
follows
EFTA01125022
a.d. winston service, inc.
JOB NAME: EPSTEIN RESIDENCE
ADDRESS: 9 EAST 71ST STREET
EQUIPMENT LIST
Description
UNIT MANUFACTURER MODEL# TONS LOCATION SERVES
SERIAL#
AC-1 CARRIER M#39E17 BSMT 1 ST FL & 2N° FL
AIRHANDLER W/ S# N/A MER EAST
CW/HW COILS
AC-2 CARRIER M#39E17 BSMT 1" & 2HD FL
AIRHANDLER W/ S# N/A MER WEST
CW/HW COILS
AC-3 CARRIER M#39E17 PENTHOUSE 3R° 4Th 5Th
AIRHANDLER W/ S# N/A MER FL
CW/HW COILS
CH-1 CARRIER M#30HK040530 40 BSMT COOLING FOR
CHILLER S#1890500778 MER FAN COILS
CH-2 MULTISTACK M# 50 BSMT COOLING FOR
MODULE CHILLER S# MER FAN COILS
CT-i BAC COOLING M#VXT30 ROOF
TOWER S# N/A
CT-2 BAC COOLING M#VXT30 ROOF
TOWER S# N/A
AC-01 7 REHEAT COIL M# BSMT AC#1 #2
ZONE VALVES S# MER
AC-02 4 REHEAT COIL M# BSMT
ZONE VALVES S# MER
AC-03 9 REHEAT COIL M# 5TH FL MASTER
ZONE VALVES S# MER BEDROOM
PURIFIL FRESH M#PSA302-72-2P- BSMT AC-O1
AIR FAN 18M-12F
S#K90-6717
AC-4 CW/HW CARRIER M#39E08 10 CATERING
FAN COIL UNIT S# N/A KITCHEN
AC-5 CW/HW CARRIER M#42DD06 2.5 RM 523 LIVING
FAN COIL UNIT S# N/A ROOM
AC-6 CW/HW CARRIER M# 42DD05 2 RM 304
FAN COIL UNIT S# N/A BEDROOM
STAIRS
AC-8 CARRIER FAN M# 42DD08 RM 607 STAFF
COIL UNIT S# N/A DAY ROOM
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 3
EFTA01125023
a.d. winston service, inc.
JOB NAME: EPSTEIN RESIDENCE
ADDRESS: 9 EAST 71ST STREET
EQUIPMENT LIST
DESCRIPTION
UNIT MANUFACTURER MODEL# TONS LOCATION SERVES
SERIAL#
AC-9 CW CARRIER FAN M#50AH024 2 AUDIO VISUAL
COIL UNIT S# N/A
AC-10 CW/HW CARRIER M#42DD05 2 RM 108
FAN COIL UNIT S# N/A SECURITY
ROOM
AC-11 CW/HW CARRIER M#39605 4 RM 013
FAN COIL UNIT S# N/A CELLAR
AC-12A FAN COIL UNIT M# N/A WINE CELLAR/
AC-12B FAN COIL UNIT M# N/A TELEPHONE
RM
AC-13 CW/HW CARRIER M# 42[002 1 RM 020
FAN COIL UNIT S# N/A CELLAR
LAUNDRY
AC-15 CW TRANE FAN M#WPRD019 2 SECURITY
COIL UNIT S# N/A CLOSET
W/ELECTRIC
HEAT
AC-16 CW CARRIER FAN M#42DD3 2.5 SUBCELLR
COIL UNIT S# N/A
AC-17 CW/HW CARRIER M#42DD05 2 RM 505
FAN COIL UNIT S# N/A SOUTH
BEDROOM
P-1 WEINMAN M#1.5 KHB 10HP SUBCELLAR CONDENSER
CONDENSER WATER
WATER PUMP
P-2 WEINMAN M#1.5 KHB 10HP SUBCELLAR CONDENSER
CONDENSER WATER
WATER PUMP
P-3 WEINMAN M#1.5KHB 10HP SUBCELLAR CONDENSER
CONDENSER WATER
WATER PUMP STANDBY
P-4 WEINMAN M#1.5KHB 3 HP SUBCELLAR CHILLED
CHILLED WATER WATER
PUMP
P-5 WEINMAN M#1.5KHB 3HP SUBCELLAR CHILLED
CHILLED WATER WATER
PUMP
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 4
EFTA01125024
a.d. winston service, inc.
JOB NAME: EPSTEIN RESIDENCE
ADDRESS: 9 EAST 71ST STREET
EQUIPMENT LIST
DESCRIPTION
UNIT MANUFACTURER MODEL# TONS LOCATION SERVES
SERIAL#
P-6 WEINMAN HOT M#1.5GTB 2 SUBCELLAR HOT
WATER PUMP WATER
P-7 WEINMAN HOT M#1.5GTB 2 SUBCELLAR HOT
WATER PUMP WATER
STANDBY
H-1 NORTEC M#HTC050 CELLAR AC-1
HUMIDIFIER S# N/A MER
W/STEAM
H-2 NORTEC M#HTC050 CELLAR AC-2
HUMIDIFIER S#N/A MER
W/STEAM
H-3 NORTEC M#HTC050 ROOF MER AC-3
HUMIDIFIER S#N/A
W/STEAM
EF-1 GREENHECK M#SWB-20 6TM FL CELLAR
UTILITY FAN CATERING
KITCHEN
EF-2 GREENHECK M#GW-100-A SIDE WALL 2ND FL MAIN
CENTRIFIGAL FAN KITCHEN
EF-3 GREENHECK M#SFB-10 SIDE WALL 157 FL
UTILITY FAN KTICHEN
EF-4 GREENHECK M#BSQ-12-4 CATERING DISHWASH
INLINEFAN KITCHEN EXH.
EF-5 GREENHECK M#GW-90-D SIDE WALL 3131)FL
CENTRIFIGAL FAN BATHROOM
EXHAUST
EF-6 KANALFLAKT M#KE20-10 6" FL CELLAR
INLINE FAN BATHROOM
EXHAUST
EF-7 GREENHECK M#GW-90-G SIDE WALL 5TH FL
CENTRIFIGAL FAN BATHRO
OM
EXHAUST
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 5
EFTA01125025
a.d. winston service, inc.
JOB NAME: EPSTEIN RESIDENCE
ADDRESS: 9 EAST 71ST STREET
EQUIPMENT LIST
DESCRIPTION
UNIT MANUFACTURER MODEL# TONS LOCATION SERVES
SERIAL#
EF-8 KANALFLAKT M#KE-20-10 6T" FL 1sT 2ND FLOOR
CENTRIFIGAL FAN BATHROOM
EXHAUST
EF-9 GREENHECK M#GW-90-D SIDE WALL 4T" FL NORTH
CENTRIFIGAL FAN BATHROOM
EXAUST
EF-10 KANALFLAKT M#KE-20-10 e FL MASTERBATH
CENTRIFIGAL FAN ROOM
EXHAUST
EF-12 KANALFLAKT M#KE16-8 6 TH FL LOCKER
INLINE FAN ROOM
EXH.
EF-13 KANALFLAKT M#KE16-8 6TH FL 4T" FL SOUTH
INLINE FAN BATHROOM
EXHAUST
EF-14 GREENHECK M#GW-95-D SIDE WALL 1 ST FL NORTH
CENTRIFIGAL FAN BATHROOM
EXHAUST
EF-15 & 16 KANALFLAKT M#KK200 6TH FL BATHROOM
CENTRIFIGAL FAN KITCHEN
EF-17 & 19 KANALFLAKT M#K6 SUBCELLAR EL ROOM
CENTRIFIGAL FAN EXHAUST
EF-18 KANALFLAKT M#KE-20-126 SUBCELLAR MER
CENTRIFIGAL FAN EXHAUST
EF-20 KANALFLAKT M#K8-120 5TH FL STAFF
INLINE FAN KITCHEN
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 6
EFTA01125026
a.d. winston service, inc.
JOB NAME: EPSTEIN RESIDENCE
ADDRESS: 9 EAST 71ST STREET
EQUIPMENT LIST
DESCRIPTION
NOTE:
► FILTERS AND BELTS INCLUDED IN CONTRACT.
► 1X ANNUAL CLEANING OF MULTISTACK CHILLER AND CARRIER CHILLER.
► 2X YEAR EVAPORATOR AND HOT WATER COIL CLEANING.
► 1X YEAR REPLACEMENT OF HUMIDIFIER CYLINDERS.
► 6X YEAR INSPECTION ON PUMPS.
► 3X YEAR INSPECTION ON HUMIDIFIERS.
► 2X YEAR INSPECTION ON EXHAUST FANS.
► 6X YEAR INSPECTION ON AIRHANDLERS AND FAN COILS.
► 6X YEAR INSPECTION ON SANDFILTER.
► 1X YEAR CLEAN SUMP AND COOLING TOWER.
► 6X YEAR CLEAN MULTISTACK CHILLER STRAINERS.
► GALLO GUN CARTRIDGES INCLUDED IN CONTRACT.
NOTE:
►STEAM STATIONS FOR DOMESTIC HOT WATER SYSTEM AND HEATING SYSTEM
NOT INCLUDED IN CONTRACT.
► DDC CONTROL SYSTEM NOT INCLUDED IN CONTRACT.
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 7
EFTA01125027
a.d. winston service, inc.
PERIODIC INSPECTION and MAINTENANCE of AIR HANDLING UNIT
PRE-SEASON SERVICE
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
TURN ON SUPPLY TO COILS AND TEST T.D.
CHECK OPERATION OF CONTROLS AND CALIBRATE AS NECESSARY
CHECK SETTING OF VALVES AND DAMPERS ADJUST AND LUBRICATE AS NECESSARY
LUBRICATE FAN AND MOTOR BEARINGS TIGHTEN LOCKING NUTS AS NECESSARY
CHECK AND ADJUST FAN BELT CONDITION TENSION AND CHANGE WHERE NECESSARY
CHECK AND REPORT ON CONDITION OF AIR FILTERS AND CHANGE WHERE NECESSARY
CHECK AND CLEAN STRAINERS AND TRAPS
CHECK AND TEST CONDENSATE PUMPS AND CLEAN SUMP
CHECK BLOWER WHEELS AND COILS FOR CLEANLINESS
REPLACE ALL PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 8
EFTA01125028
a.d. winston service, inc.
MID-SEASON SERVICE INSPECTIONS
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
LUBRICATE FAN AND MOTOR BEARINGS
CHECK AND ADJUST FAN BELT CONDITION AND TENSION, CHANGE AS NECESSARY
CHECK THERMOSTATS AND CALIBRATE AS NECESSARY
CHECK AND REPORT ON CONDITION OF AIR FILTERS AND CHANGE AS NECESSARY
CHECK MOTOR AMPERAGE AGAINST F.L.A.
CHECK T.D. ACROSS COILS
REPLACE ALL PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 9
EFTA01125029
a.d. winston service, inc.
YEAR ROUND SERVICE
AIR CONDITIONING UNITS
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
CHECK CONDITION OF AIR FILTERS AND REPLACE AS NECESSARY
CHECK CONDITION OF COOLING COILS AND CONDENSER COILS, BRUSH CLEAN WHERE
NECESSARY
CHECK CONDITION OF CONDENSER TUBES AND CONDENSER PRESSURE CONTROLS
CHECK CONDITION OF PULLEY AND FLYWHEELS FOR TIGHTNESS AND CLEANLINESS
CHECK AND ADJUST FAN BELT CONDITION AND TENSION AND CHANGE WHERE NECESSARY
CHECK AND ADJUST FAN WHEEL CLEARANCE OF HOUSING AND CLEAN AS NECESSARY
TAKE T.D. ACROSS COOLING COILS AND CONDENSERS
CHECK AND CLEAN CONDENSATE DRAINS AND PANS
CHECK CONDENSATE PUMPS AND CLEAN SUMP
CHECK OPERATION OF THERMOSTATS AND CALIBRATE AS NECESSARY
CHECK OPERATING AND SAFETY CONTROLS AND CALIBRATE AS NECESSARY
TIGHTEN ALL CONNECTIONS IN CONTROL PANEL WHERE NECESSARY
CHECK REFRIGERANT CHARGE AND TEST FOR LEAKS WHERE NECESSARY
CHECK COMPRESSOR OPERATING PRESSURES
LUBRICATE MOTORS AND BEARINGS, AND TIGHTEN LOCKING COLLARS
CHECK AMPERAGE OF MOTOR COMPRESSORS AGAINST F.L.A.
CHECK AND ADJUST VALVES
REPLACE ALL PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 10
EFTA01125030
a.d. winston service, inc.
YEAR ROUND SERVICE (Cont.)
COOLING TOWER AND DRY COOLER
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
CLEAN ALL STRAINERS
LUBRICATE PUMP. BLOWER AND MOTOR BEARINGS AND TIGHTEN LOCKING COLLARS
CHECK BLOWER BELT CONDITION AND TENSION ADJUST AND REPLACE AS NECESSARY
CLEAN ANY CLOGGED NOZZLES AND REPLACE AS NECESSARY
INSPECT WATER RESERVOIR FOR CLEANLINESS AND CORROSION AND AS NECESSARY
CHECK OPERATION OF WATER LEVEL FLOAT VALVE AND ADJUST WHERE NECESSARY
CHECK WATER PUMP PACKING AND SEALS AND ADJUST AS NECESSARY
CHECK WATER LINES FOR LEAKS AND REPAIR AS NECESSARY
CHECK AND ADJUST VALVES AND DAMPERS AND LUBRICATE SAME
CHECK OPERATION AND SAFETY CONTROLS. ADJUST AND REPLACE AS NECESSARY
CHECK CIRCULATING PUMPS FOR PROPER OPERATION
CHECK HEAT TAPE AND ASSOCIATED CONTROLS
CHECK AND REPORT ON CONDITION OF TOWER IN GENERAL
CHECK FAN MOTOR AND BLADES FOR PROPER OPERATION AND CLEARANCES
CHECK AMPERAGE OF MOTOR AND PUMPS AGAINST F.LA.
CHECK GLYCOL LEVEL AND ADD WHERE NECESSARY
CHECK COILS FOR CLEANLINESS AND CLEAN AS NECESSARY
TIGHTEN ALL ELECTRICAL CONNECTIONS AND CONTROL PANELS AND DISCONNECTS
REPLACE ALL PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 11
EFTA01125031
a.d. winston service, inc.
INSPECTION OF PUMPS
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
CLEAN STRAINERS
CHECK POSITION OF BALANCING VALVE
TEST OPERATION OF MAIN CHECK VALVE
LUBRICATE PUMP AND MOTOR AS REQUIRED
CHECK AMPERAGE OF PUMP MOTOR AGAINST F.L.A.
CHECK SEALS AND BEARINGS FOR NOISE AND FREE PLAY AND REPORT ANY PROBLEMS
IMMEDIATELY
CHECK PUMP MOUNTS AND VIBRATION ELIMINATORS
DURING DRAIN DOWN REMOVE PLUGS FROM PUMP HOUSING TO PREVENT FREEZE UP.
REINSTALL PLUGS.
CHECK PUMP TO MOTOR COUPLING FOR WEAR VIBRATION OR NOISE ADJUST AND OR
REPLACE AS REQUIRED
REPLACE ALL PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 12
EFTA01125032
a.d. winston service, inc.
INSPECTION OF HEATING COILS STEAMANATER
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
CHECK COILS FOR CLEANLINESS, BRUSH CLEAN AS NECESSARY
CHECK T.D. ACROSS COILS AND REPORT ANY INCORRECT READINGS IMMEDIATELY
CHECK PRESSURE DROP ACROSS COILS AND REPORT WHERE APPLICABLE, REPORT ANY
INCORRECT READINGS IMMEDIATELY
PULL AND CLEAN ALL STRAINERS AND REPLACE ANY BASKETS AS NECESSARY
CHECK AND TEST OPERATIONS OF CONTROL VALVES
CHECK CONDITION OF COIL FINS, COMB OUT BENT FINS WHERE NECESSARY
CHECK COILS FOR CORROSION AND OXIDATION OF ALL TUBES FINS AND HEADERS
CHECK OPERATION OF ANY AIR VENTS AND VACUUM BREAKERS
REPLACE ALL ACCESS DOORS /PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 13
EFTA01125033
a.d. winston service, inc.
INSPECTION OF EXHAUST FANS
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
LUBRICATE MOTOR BEARINGS AS REQUIRED
LUBRICATE FAN BEARINGS AND CHECK SHAFT FOR WEAR AND TEAR
TIGHTEN LOCKING COLLARS ON FAN BEARINGS
CHECK BELTS FOR WEAR, ADJUST TENSION AND OR REPLACE AS NECESSARY
CHECK MOTOR AND FAN PULLEYS FOR WEAR AND CORRECT ALIGNMENT
CHECK AND TEST MOTOR AMPERAGE AGAINST F.L.A.
CHECK OUTDOOR FANS FOR CORROSION
REPLACE ALL ACCESS COVERS/PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 14
EFTA01125034
a.d. winston service, inc.
INSPECTION OF LINE AND LOW VOLTAGE ELECTRICAL MAINTENANCE
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
TIGHTEN ALL LINE VOLTAGE LUGS AND SCREW TERMINALS ON THE FOLLOWING CONTROLS
AND SWITCHES, INCLUDING LOW VOLTAGE STATIONS AND CONNECTORS
- DISCONNECT SWITCHES
- STARTERS
- CONTACTORS
- RELAYS
- TOGGLE AND ROTARY SWITCHES
- CONNECTORS AND WIRE NUTS
- FUSE BLOCKS
- SAFETY CONTROLS
- OPERATING CONTROLS
- MODULES AND CONTROLLERS
- COMPRESSOR AND MOTOR TERMINAL BOXES
CHECK FOR BURNT WIRES AND REPLACE AS NECESSARY
CHECK ALL KNIFE SWITCHES AND FUSE BLOCKS FOR TIGHT CONTACT ADJUST AS NECESSARY
CHECK ALL CONTACTS ON STARTERS, CONTACTORS AND RELAYS FOR PITTING AND BURNING,
REPLACE AS NECESSARY
CHECK FOR CORRECT VOLTAGE AND PHASING
CHECK FOR CORRECT AMPERAGE AN ALL MOTORS COMPRESSORS AND HEATERS
CHECK FOR CORRECT FUSE SIZE AND OVER LOAD PROTECTION
CHECK FOR CORRECT HEATER SIZE ON STARTERS
REPLACE ALL ACCESS DOORS /PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 15
EFTA01125035
a.d. winston service, inc.
INSPECTION OF MAKE UP FANS AND H&V UNITS
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
CHECK AND ADJUST BELT TENSION, REPLACE AS NECESSARY
CHECK MOTOR AND FAN PULLEYS FOR WEAR AND ALIGNMENT
CHECK AND TIGHTEN ALL PULLEY SET SCREWS FOR PITCH ADJUSTMENT AS WELL AS
MOUNTING SET SCREWS
LUBRICATE FAN BEARINGS AS NECESSARY
TIGHTEN FAN BEARING LOCKING COLLAR AND TIGHTEN SET SCREWS
CHECK OPERATION OF ALL DAMPERS AND LUBRICATE DAMPER SHAFTS AND BEARINGS
CHECK CONDITION OF BLOWER WHEEL FOR WEAR AND CLEANLINESS, CLEAN AS NECESSARY
CHECK COILS FOR CLEANLINESS AND FIN CONDITION, BRUSH CLEAN AS NECESSARY
CHECK AND TEST CONTROLS FOR CORRECT OPERATION, REPAIR, CALIBRATE AND REPLACE
AS REQUIRED
CHECK OPERATION OF ALL DAMPER MOTORS AND VALVE MOTORS AND ADJUST AS
NECESSARY
CHECK AND TEST OPERATION OF ELECTRIC HEATING COILS
TAKE T.D. ACROSS ALL COILS TO TEST FOR CORRECT OPERATION AND REPORT AND
PROBLEMS IMMEDIATELY
CHECK FAN MOUNTINGS AND VIBRATION ELIMINATORS FOR WEAR AND TIGHTNESS
PULL ALL STRAINERS AND CLEAN BASKETS AND REPLACE BASKETS AS NECESSARY
REPLACE ALL ACCESS COVERS AND PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 16
EFTA01125036
a.d. winston service, inc.
CHILLERS AIR COOLED/ WATER COOLED
PERIODIC INSPECTION & MAINTENANCE OF CHILLERS
VISUAL INSPECTION OF ALL EQUIPMENT
SPEAK TO CUSTOMER FOR ANY COMPLAINTS AND CONCERNS
CHECK CONDITION OF CONDENSER COILS, BRUSH CLEAN WHERE NECESSARY
CHECK CONDITION OF CONDENSER TUBES AND CONDENSER PRESSURE CONTROLS
TAKE T.D. AND PRESSURE DROP ACROSS CHILLED WATER AND CONDENSER WATER
BUNDLES
CHECK AND CLEAN STRAINERS ONCE PER YEAR
CHECK OPERATION OF THERMOSTATS AND CALIBRATE AS NECESSARY
CHECK OPERATING AND SAFETY CONTROLS AND CALIBRATE AS NECESSARY
TIGHTEN ALL CONNECTIONS IN CONTROL PANEL WHERE NECESSARY
CHECK REFRIGERANT CHARGE AND TEST FOR LEAKS WHERE NECESSARY
CHECK COMPRESSOR OPERATING PRESSURES
LUBRICATE MOTORS AND BEARINGS, AND TIGHTEN LOCKING COLLARS
CHECK AMPERAGE OF MOTOR COMPRESSORS AGAINST F.L.A.
REPLACE ALL PANELS AND SCREWS
CLEAN AREA
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 17
EFTA01125037
a.d. winston service, inc.
HUMIDIFIER MAINTENANCE
TEST HI LIMIT HUMIDISTAT FOR PROPER OPERATION
TEST HUMIDISTAT CONTROLLER FOR PROPER OPERATION
SEQUENCE TEST THE HUMIDIFIER
CHECK ELECTRICAL POWER CONNECTIONS
CHECK OVERFLOW PAN
CHECK HUMIDIFIER DRAIN VALVE
CHECK HUMIDIFIER FLOAT AN OR ELECTRONIC LEVEL CONTROLS
INSPECT SAFETY SWITCHES, HI TEMPERATURE CUT-OFFS
REMOVE AND CLEAN THE HUMIDIFIER CANISTER (STAINLESS STEEL)
INSPECT AND CLEAN THE HEATING ELEMENT
REMOVE AND REPLACE THE HUMIDIFIER STEAM GENERATOR (BASED ON HOURS OF OPERATION
OR MANUFACTURE SPEC TYPICALLY 2000 HRS DEPENDING ON WATER CONDITION.
CHECK WATER SUPPLY
CHECK DRAIN HOSES
INSPECT THE CONDITION OF THE FLEXIBLE STEAM DELIVERY HOSES
VISUALLY INSPECT FOR WATER LEAKS, RUST AND CORROSION
REPORT ANY DEFICIENCIES FOUND TO THE CUSTOMER
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 18
EFTA01125038
a.d. winston service, inc.
EXCLUSIONS
■ First time repairs of inoperative and/ or malfunctioning equipment at time of contract acceptance or
seasonal start-up where equipment is not operational at time of contract acceptance (e.g., If
contract is issued during heating season, first time repairs of cooling equipment cannot be
performed until start of cooling season.)
• Labor and materials to dean Water Cooled Condensers.
• Cooling Tower Chilled Water, Condenser Water, or Boiler Water Treatment.
• Labor and Materials to Pressure Wash, or Steam Clean Air Cooled Condensers and Evaporators.
• Labor and material to change compressors, condensers, evaporator coils, heat exchangers and fan
sections.
■ Labor and materials to change pumps, motors 3HP and above, and any repairs requiring two
technicians.
■ Labor and material to change shaft and bearings if two technicians are required.
■ High pressure refrigerant leak testing as well as isolation of components.
• Electrical Services, Disconnect Switches and Starters External to Units, Water Services and Drains.
■ Cabinets, Ductwork, Diffusers, and Air Balancing.
■ Moving or relocating the equipment.
• Asbestos Removal and Abatement
• Parking Fees
TERMS AND ACCEPTANCE
In consideration for the Planned Inspection, Maintenance, and Emergency Services listed above
EPSTEIN RESIDENCE 9 EAST 71" STREET NEW YORK, NY 10021 agrees to pay the sum of
$50,376.00 plus applicable sales tax for the term of this agreement. Payment shall be made
QUARTERLY in advance in the amount of $12,594.00 plus applicable sales tax prior to the starting
date of this agreement. All additional service work shall be paid for thirty days after the date of
invoices. a.d. winston service inc. may withhold service if your account is in arrears, and until such
time as the account is made current, will not be liable for credit or counter claims.
This contract and its provisions covers all agreements between us in respect to the air conditioning,
refrigeration, heating and such allied equipment as is described in this agreement. No verbal
agreements or understandings shall change or modify the terms of this agreement. This contract
becomes effective when duly signed by an authorized member of your company and countersigned by
an officer of a.d. winston service inc.
a.d. winston service inc. EPSTEIN RESIDENCE:
By: Mauro A. Palladino By:
President & Gen.Mgr. Title:
Authorized Signature / Date Authorized Signature & Start Date
eaki A itagoike
PRESIDENT d st
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 19
EFTA01125039
a.d. winston service, inc.
LABOR RATES
REGULAR RATES 8:00 A.M. TO 4:30 P.M. $128.00/HR
WEEKDAYS ONLY
HOURLY RATE
OVERTIME RATE 4:30 P.M. TO 7:59 A.M. $192.00/HR
WEEKDAYS AND ALL
DAY SATURDAY
DOUBLE TIME RATE ALL DAY SUNDAY $256.00/HR
AND HOLIDAYS
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 20
EFTA01125040
a.d. winston service, inc.
INVOICE
INVOICE DATE: 02/1/11
INVOICE #: MC 020111
NES, LLC
9 EAST 71ST STREET
NEW YORK, NY 10021
ATT: RICHARD BARNETT
SITE NAME: EPSTEIN RESIDENCE
9 EAST 71sT STREET
NEW YORK, NY 10021
DESCRIPTION AMOUNT
Maintenance Contract Billing covering your
H.V.A.C. Contract for upon acceptance
For $50,376.00
NOTE: Please sign and return (1) copy
of signature page of agreement
with payment.
Quarterly Billing $12,594.00
Sales Tax $1,117.71
Amount Due $13,711.71
COMPLETE INDUSTRIAL AND COMMERCIAL HVAC SERVICE AND MAINTENANCE
Page 21