📄 Extracted Text (883 words)
Corporate Headquarters Tennessee Office
6855 Lyons Technology Circle • Suite 18 1107 Battlewood Street
SLICK STEEL Coconut Creek • FL • 33073 Franklin • TN • 37069
CUSTOMER QUOTE
Name Brice Gordon Tel Quote Date
Company LSJ Employees. LLC Fax Valid Through
Street Email Project ID BS23415
City Sales Rep Brian Buck
State
Country US Virgin Islands Page 1 of 2
Project Building 2
Location Street TBD City TBD County TBD
State ZZ Zip TBD Country US Virgin Islands
Engineering
Width 60' Code IBC 2009 Snow Gnd 0 Seismic Ss Shell Enclosed Occupancy Normal
Length 120' Wind Load 145 MPH Snow Roof 0 Seismic S1 Column Tapered Thermal Unheated
Height 12' Exposure C Snow Is 1.0 Base Deluxe Formed Trim Snow Exp Sheltered
Roof Pitch 1.5:12 Live Load 20 Snow CI 1.0 Collateral 0.5 Frame Gable Symmetrical
Reducible Yes Snow Ce 1.0
Left Endwall Spacing 25'i23'6721'6" Type Post and Beam Bracing Cable Girt Bypass
Right Endwall Spacing 21'6723'6725' Type Post and Beam Bracing Cable Girt Bypass
Front Sidewall Spacing 2174@20121' Type N/A Bracing Cable Girt Bypass
Back Sidewall Spacing 2174@20121' Type N/A Bracing Cable Girt Bypass
Primary Frame Coating Red Oxide Primer Secondary Frame Coating Red Oxide Primer
Roof Panel Gauge 24 Style RROL Screw Type•Length Long Life-1 1/4' Color Not Specified
Wall Panel Gauge 24 Style PBR Screw Type•Length Long Life-1 1/4* Color Not Specified
Engineering EXPORT BUILDING with final destination of XXXX via PORT )000( with unloading and freight forwarding by others. Export package includes
Notes extra sheeting. nuts. bolts. fasteners, girls and puslins with all rollup doors specifically crated for export to provide additional protection. It is the
customers responsibility to VERIFY All CODES & LOADS used to design this budding as being in accordance with local requirements. Total
weight is estimated as XXXXX lbs. COD amount is to be paid in full 2 weeks prior to delivery to port
Building Pricing
Oty Description
1 Base Building as per Engineering Specifications Included
1 Stamped Engineered Building Drawings (3 Sets) Included
1 Eroding Drawings (2 Sets) Included
1 Letter of Certification Included
1 Anchor Boll Plans Included
1 All Frames Hot-Dipped Galvanized, Secondary Members Pre-Galvanized Included
1 FSW 1'. 53'64" Below BSW Grade Included
1 LEW. BSW Open to 5%6" For Block. REW Open to 2-4' For Block Included
5 Misc Steel Columns To Support Roof From Below Floor(Max 301b. per ft. Bracing At Floor W/Hdware Included
1 Mod-2 Design 40'. 20' Framelines 8246 Included
1 Full Trim Package Including: Corner Trim. Eave Trim, Sculptured Rake Trim Included
1 Die-formed Ridge Cap Included
1 Closure Strip Package Included
1 Gutters 8 Downspouts Included
2 Framed Opening Standard 18' x 10' Rolling Steel Doors Included
1 Framed Opening Standard 4' x 4' For CUSTOMER Provided Louvers Included
2 Framed Opening Standard 5' x 4'. 1' AFF For CUSTOMER Provided Louver Included
1 Personnel Door 30704 White Insulated Pre-Assembled Windlock Certified w/ Lever Handle w/ Threshold Included
2 Roll Up Windlock Certified Non-Insulated w/Chainhoist 18' x 10' Included
1 Roof Insulation GI R19 WMP-VR w/ Starter Roll w/ Patch Tape Included
1 Wall Insulation 4"/ R13 WMP-VR w/ Starter Roll w! Patch Tape Included
1 Building 8 Accessory Freight To Port Everglades Included
1 Export Package Including Extra Compnents and Special Crating Included
Total Building 83,640.00
Florida Tennessee Website
Tel Tel: www.bucksteel.com
EFTA00798570
Corporate Headquarters Tennessee Office
6855 Lyons Technology Circle • Suite 18 1107 Balllewood Street
SLICK STEEL Coconut Creek • FL • 33073 Franklin • TN • 37069
CUSTOMER QUOTE
Name Seco Gordon Tel Quote Date
Company LSJ Employees. LLC Fax Valid Through
Street Email Project ID BS23415
City Sales Rep Brian Buck
State
Country US Virgin Islands Page 2 of 2
IMPORTANT NOTES - PLEASE READ
• This quote is based on Buck Steers interpretation of plans and/or conversations with the customer, Buck Steel is NOT responsible for
any errors and/or ommissions.
• Carefully check this quote for completeness and verify the accuracy of the information contained within.
• This quote is valid through , and is subject to review of pricing. Revisions to quote may result in a price adjustments.
• Erecting is NOT included in this quote, unless specifically listed.
• Erecting estimate is based upon. but not limited to. pad being accessible for a clear 25' around entire building, no trees, powerlines or
equipment which may interfere with erecting. and power supplied to slab. Erecting estimate does not take into consideration any OSHA,
Davis Bacon. special insurance requirements, or limit to days and times erecting crews are permitted to work.
• Accessories not provided by Buck Steel (including but not limited to: windows, doors. cupolas. vents, fans, lighting, stucco, masonry etc.)
will not be installed by the erector unless otherwise specified.
• Anchor bolts are NOT included in this quote and are NOT provided by Buck Steel.
• Concrete is NOT included in this quote and is NOT provided by Buck Steel
• Buck Steel and/or the Building Engineer is NOT the "Engineer of Record'. The customer/owner is responsible for any "special building
inspector or "structural engineer required by the city or county for pre and post construction inspections.
• All prices are in USO.
• Sales tax is NOT included in this quote.
Questions about this quote?
Contact Brian Buck at
Florida Tennessee Webslte
www.bucksteel.com
EFTA00798571
ℹ️ Document Details
SHA-256
71283c68ae7fc4d64f5307dfda06cae6c35f2b3b906749db2017ed4b927df057
Bates Number
EFTA00798570
Dataset
DataSet-9
Document Type
document
Pages
2
Comments 0