📄 Extracted Text (1,526 words)
Corporate Headquarters Tennessee Office
6855 Lyons Technology Circle • Suite 18 1107 Balllewood Street
SLICK STEEL Coconut Creek • FL • 33073 Franklin • TN • 37069
CUSTOMER QUOTE
Name Brace Gordon Tel Quote Date 01/31/2017
Company LSJ Employees. LLC Fax Valid Through 02/07/2017
Street Email Project ID BS23416
City Sales Rep Brian Buck
State
Country US Virgin Islands Page 1 of 4
Project Building I
Location Street City TBD County TBD
State ZZ Zip TBD Country US Virgin Islands
Engineering
Width Code IBC 2009 Snow Gnd 0 Seismic Ss Shell Enclosed Occupancy Normal
Length 80' Wind Load 145 MPH Snow Roof 0 Seismic S1 Column Tapered Thermal Unheated
Height 18' Exposure C Snow Is Base Deluxe Formed Trim Snow Exp Sheltered
Root Pitch 1.5:12 Live Load 20 Snow Ct Collateral 0.5 Frame Gable Symmetrical
Reducible Yes Snow Ce
Left Endwall Spacing 28% 24'. 2B' Type Full-Load Expandable Frame Bracing None Girt Flush
Right Endwall Spacing 28% 24'. 2B' Type Non-Expandable Bearing Frame Bracing Cable Girt Flush
Front Sidewall Spacing 4@20' Type N/A Bracing Cable Girt Bypass
Back Sidewall Spacing 4@20' Type N/A Bracing Cable Girt Bypass
Primary Frame Coating Red Oxide Primer Secondary Frame Coating Red Oxide Primer
Roof Panel Gauge 24 Style PBR Screw Type•Length Long Life-1 1/44 Color Not Specified
Wall Panel Gauge 24 Style PBR Screw Type•Length Long Life-1 1/4• Color Not Specified
Engineering EXPORT BUILDING with final destination of XXXX via PORT )000( with unloading and freight forwarding by others. Export package includes
Notes extra sheeting. nuts. bolts. fasteners, gins and pudins with all rollup doors specifically crated for export to provide additional protection. It is the
customer's responsibility to VERIFY All CODES & LOADS used to design this budding as being in accordance with local requirements. Total
weight is estimated as XXXXX lbs. COD amount is to be paid in full 2 weeks prior to delivery to port.
Building Pricing
Oty Description
1 Base Building as per Engineering Specifications Included
1 Stamped Engineered Bulking Drawings (3 Sets) Included
1 Erecling Drawings (2 Sets) Included
1 Letter of Certification Included
1 Anchor Boll Plans Included
1 LEW Bay #1 Open to Building "B" Included
1 Mod-2 design. Columns at 28 From Back Side Wall Included
1 Full Trim Package Including: Corner Trim, Eave Trim. Sculptured Rake Trim Included
1 Die-formed Ridge Cap Included
1 Closure Strip Package Included
1 Gutters & Downspouts Included
7 Framed Opening Standard Misc. Sizes For CUSTOMER Provided Louvers Included
1 Framed Opening Standard. 12' x it. LEW, Bay #2.5' From Column Included
1 Framed Opening Standard, 12' x 16', LEW. Bay #3. 12' From Column Included
1 Framed Opening Standard. 12' x REW. Bay #1, 5' From Column Included
1 Framed Opening Standard, 12' x 16', REW. Bay 92.8' From Column Included
4 Rollup Door Windlock Certified Non-Insulated wr Chainhoist 12' x 16' Included
1 Roof & Wall Insulation 37 R10 WMP•VR w/ Starter Roll w/ Patch Tape Included
1 Building & Accessory Freight To Port In Ronda Included
Florida Tennessee Webslte
EFTA00798572
Corporate Headquarters Tennessee Office
6855 Lyons Technology Cute • Suite 18 1107 Battlewood Streel
SLICK STEEL Coconut Creek • FL • 33073 Franklin • TN • 37069
CUSTOMER QUOTE
Name Brice Gordon Tel Quote Date 01131/2017
Company LSJ Employees. LLC Fax Valid Through 02/07/2017
Street Email Project ID BS23416
City Sales Rep Brian Buck
State
Country US Virgin Islands Page 2 of 4
Project Building 2
Location Street City TBD County TBD
State ZZ Zip TBD Country US Virgin Islands
Engineering
Width 28' Code IBC 2009 Snow Gnd 0 Seismic Ss Shell Occupancy Normal
Length 25' Wind Load 145 MPH Snow Roof 0 Seismic S1 Column Tapered Thermal Unheated
Height 16' Exposure C Snow is Base Snow Exp Sheltered
Roof Pitch 1.5:12 Live Load 20 Snow CI Collateral 0.5 Frame
Reducible Yes Snow Ce
Left Endwall Spacing 28' Type Half-Load Non-Expandable Frame Bracing None Girt Flush
Right Endwall Spacing 28' Type Half-Load Non-Expandable Frame Bracing None Girt Flush
Front Sidewall Spacing 25' Type N/A Bracing None Girt Bypass
Back Sidewall Spacing 25' Type N/A Bracing None Girt Bypass
Primary Frame Coating Red Oxide Primer Secondary Frame Coating Red Oxide Primer
Roof Panel Gauge 24 Style PBR Screw Type-Length Long Life-1 1/4" Color Not Spedtied
Wall Panel Gauge 24 Style PBR Screw Type-Length Long Life-1 1/4' Color Not Specified
Engineering REW of Building Attaches to LEW of Building 'X
Notes
Building Pricing
Oty Description
1 Base Building as per Engineering Specifications Included
1 Stamped Engineered Builchng Drawings (3 Sets) Included
1 Erecting Drawings (2 Sets) Included
1 Letter of Certification Included
1 Anchor Bolt Plans Included
1 BSW Open to 10' for 12" Poured Concrete Wall Included
1 LEW Open To Existing Bldg Same Width. Height. Roof Pitch Included
1 Full Trim Package Including: Corner Trim, Eave Trim. Sculptured Rake Trim Included
1 Die-formed Ridge Cap Included
1 Closure Strip Package Included
1 Gutters & Downspouts Included
1 Canopy Roof Extension BSW 4' Entire Length. Sheeted 6' To Top Of Existing Wall Included
1 Framed Opening Standard 1Z x 1Z For Rollup Door Included
1 Framed Opening Standard Misc. For CUSTOMER Supplied Louver Included
1 Rollup Door Windlock Certified Non-Insulated vd Chainhoist 12' x 12' Included
1 Roof & Wall Insulation 3"/ RIO WMP-VR w/ Starter Roll w/ Patch Tape Included
1 Building & Accessory Freight To Port In Florida Included
Florida Tennessee Website
EFTA00798573
Corporate Headquarters Tennessee Office
6855 Lyons Technology Circle • Suite 16 1107 Balllewood Street
SLICK STEEL Coconut Creek • FL • 33073 Franklin • TN • 37069
CUSTOMER QUOTE
Name Brice Gordon Tel Quote Date 01/31/2017
Company LSJ Employees. LLC Fax Valid Through 02+07/2017
Street Email Project ID BS23416
City Sales Rep Brian Buck
State
Country US Virgin Islands Page 3 of 4
Project Building 3
Location Street City TBD County TBD
State ZZ Zip TBD Country US Virgin Islands
Engineering
Width 32t Code IBC 2009 Snow Gnd 0 Seismic Ss Shell Occupancy Normal
Length 47'6" Wind Load 145 MPH Snow Roof 0 Seismic S1 Column Tapered Thermal Unheated
Height 16' Exposure C Snow Is Base Snow Exp Sheltered
Root Pitch 1.5:12 Live Load 20 Snow Ct Collateral 0.5 Frame
Reducible Yes Snow Ce
Left Endwall Spacing NA Type Non-Expandable Bearing Frame Bracing Cable Girt Flush
Right Endwall Spacing NA Type Non-Expandable Bearing Frame Bracing Cable Girt Flush
Front Sidewall Spacing NA Type N/A Bracing Cable Girt Bypass
Back Sidewall Spacing NA Type N/A Bracing Cable Girt Bypass
Primary Frame Coating Red Oxide Primer Secondary Frame Coating Red Oxide Primer
Root Panel Gauge 24 Style PBR Screw Type-Length Long Life.1 1/4' Color Not Specified
Wall Panel Gauge 24 Style PBR Screw Type-Length Long Life-1 1/4' Color Not Specified
Engineering Materials Only included to resheet customers existing building as per architectural drawings. Includes all Wall Sheeting. Roof Sheeting. Ridge
Notes Caps. Mastic. Closure Ships and Fastners. Colors to match new building colors(tbd by customer).
Building Pricing
Oty Description
Base Building as per Engineering Specifications Included
1 Die-formed Ridge Cap Included
1 Closure Strip Package Included
1 Building 8 Accessory Freight to Port In Florida Included
Florida Tennessee Webslte
www.bucksteel.com
EFTA00798574
Corporate Headquarters Tennessee Office
6855 Lyons Technology Circle • Suite 18 1107 Battlewood Street
SLICK STEEL Coconut Creek • FL • 33073 Franklin • TN • 37069
CUSTOMER QUOTE
Name Brice Gordon Tel Quote Date 01131/2017
Company LSJ Employees. LLC Fax Valid Through 02/07/2017
Street Email Project ID BS23416
City Sales Rep Brian Buck
State
Country US Virgin Islands Page 4 of 4
Project Price 108850.00
Freight Included
Project Total 106.850.00
IMPORTANT NOTES - PLEASE READ
• This quote is based on Buck Steers interpretation of plans and/or conversations with the customer, Buck Steel is NOT responsible for
any errors and/or ommissions.
• Carefully check this quote for completeness and verify the accuracy of the information contained within.
• This quote is valid through 2,7/2017. and is subject to review of pricing. Revisions to quote may result in a price adjustments.
• Erecting is NOT included in this quote, unless specifically listed.
• Erecting estimate is based upon. but not limited to. pad being accessible for a clear 25' around entire building, no trees, powerlines or
equipment which may interfere with erecting. and power supplied to slab. Erecting estimate does not take into consideration any OSHA,
Davis Bacon. special insurance requirements, or limit to days and times erecting crews are permitted to work.
• Accessories not provided by Buck Steel (including but not limited to: windows, doors. cupolas. vents, fans, lighting, stucco, masonry etc.)
will not be installed by the erector unless otherwise specified.
• Anchor bolts are NOT included in this quote and are NOT provided by Buck Steel.
• Concrete is NOT included in this quote and is NOT provided by Buck Steel
• Buck Steel and/or the Building Engineer is NOT the "Engineer of Record'. The customer/owner is responsible for any "special building
inspector or "structural engineer required by the city or county for pre and post construction inspections.
• All prices are in USD.
• Sales tax is NOT included in this quote.
Questions about this quote?
Contact Brian Buck at
Florida Tennessee WebsIle
www.bucksteel.com
EFTA00798575
ℹ️ Document Details
SHA-256
885fa480b230c4a0065cb082c12724a9325c23bf4ca0ed871be1a0dc7fcc6d5d
Bates Number
EFTA00798572
Dataset
DataSet-9
Document Type
document
Pages
4
Comments 0