Commercial 6 Industrial HVAC Systems • Complete Service Contracts • 24 Hour Emergency Service 434 5 36th Stneet Long Island City New York 11101 m718.361.2811 FAX 718.361.5798 www.adwinstonseneice.com Epstein Residence June 19, 2012 9 East 71st Street New York, NY 10021 Richard Barnett Dear Mr. Barnett: Pursuant to our recent survey the following is our proposal to provide and install the following equipment and services. SCOPE OF WORK :• Disconnect, remove, and dispose of the old 40-ton Carrier chiller from basement mechanical equipment room. 4• Provide, rig and install (1) new additional 30 ton Multistack module to attach to the existing chiller. + Disconnect, remove and dispose of old BAC Cooling towers and remote sump. + Provide, rig and install (2) new 52-ton BAC galvanized cooling towers to roof and pipe into existing condenser water system. + Provide, rig and install (1) new remote sump (galvanized) in basement mechanical room and pipe into existing condenser water system. :• Change filter media on existing sand filter. •3 Provide protection to entrance hall and steps for deliveries. •• All necessary materials and labor to pipe chiller. ❖ All necessary materials and labor to install power wiring for chiller. ❖ Insulation of all new chill water piping and damaged insulation that may be disturbed during tie in of components. o'• Chill water and condenser water balncing. ❖ Rubbish removal and carting away from site ❖ Factory supervised start-up, and one-year warranty on entire project. 4• Five-year warranty on new compressors (Part only) + All labor and supervision to complete the above scope of work. Price: $357,255.00 Three Hundred Fifty Seven Thousand Two Hundred Fifty Five Dollars (plus applicable sales tax) Price valid for 30 days. EFTA01102371 Add/Alternate: Please add $22,656.00 Twenty Two Thousand Six Hundred Fifty Six Dollars to the above price for the installation of (2) VFD's to control the cooling tower fans. (BMS system and/or control wiring is excluded from this price) Exclusions: Patching, Painting, Overtime, Electrical control wiring, BMS work and controls/control valves, Filing of permits if necessary, Sales tax, and any items not listed in our proposal. Payment terms: 1//3 upon acceptance, 1/3 upon delivery of equipment and 1/3 upon completion. Please sign the approval line should you wish for us to proceed with the above scope of work. I thank you for the opportunity of submitting this proposal, and I assure you of my continued personal attention. We hereby authorize a.d. winston service. to proceed with the following scope of work. Accepted By: Date: S alladino Vice President 2 EFTA01102372
ℹ️ Document Details
SHA-256
e00daca63f0181afea3d6f5d1ff23ee1b9c36bbb98df8eed5856bc73dbbd1dfb
Bates Number
EFTA01102371
Dataset
DataSet-9
Type
document
Pages
2

Community Rating

Sign in to rate this document

📋 What Is This?

Loading…
Sign in to add a description

💬 Comments 0

Sign in to join the discussion
Loading comments…
Link copied!